background image

15

For 230 Volt Units:

ITEM NO    PART NO   DESCRIPTION                   QTY

46

761-725 Power Cord

1

48

770-593 On/Off Plate

1

49

765-083 Toggle Switch

1

50

765-072 Wire

3

51

700-720 230V Fuse 10 Amp

2

54

765-050 Motor Starter

1

313-098 Earth Symbol Label

1

60

765-087 Lock Nut

1

61

765-089 Fuse Block Assembly

1

(See pages 18,19 & 20 for additional and related diagrams.)

NEUTRAL

(BLUE)

FUSES

LINE

(BROWN)

GROUND

(YELLOW-GREEN)

POWER

SWITCH

PRESSURE

SWITCH

MOTOR

240V  50.0  A

SOLID STATE

RELAY

1

2

3

4

NC

Electrical Schematic for 230 Volt Motors

230V Service Instructions

54

51

50

49

48

46

60

61

Figure 3B

Figure 3A

WARNING: Before proceeding, follow the Pressure Relief
Procedure outlined on Page 5.  Additionally, follow all
other warnings to reduce the risk of an injection injury,
injury from moving parts or electric shock.  Always unplug
the sprayer before servicing!

On/Off Switch Replacement

1. Remove Cover Plate and screws (#56 & #55). See pg. 20.
2. Disconnect the four wires from the On/Off Switch (#49).
3. Remove the rubber boot and plate (#47 & #48) with a
wrench.
4. Remove the On/Off Switch (#49).
5. Install a new Switch and reattach plate and rubber boot.
Tighten securely.
6. Reconnect the four wires to the new On/Off Switch.
7. Reinstall Switch Cover Plate and screws, with warning
label facing out.

Power Supply Cord Replacement

1. Remove Cover Plate and screws (#55 & #56). See pg. 20.
2. Disconnect the Power Supply Cord (#46) from; a) the
Fuse Holders on #61, and, b) the green wire  connected to
the grounding screw (#42).  Refer to the Electrical
Schematic, Figure 3A.

3. Loosen the cord grip housing (#45) and remove the power
cord (#46).
4. Install the new cord in reverse order of disassembly.
5. Install the cover and screws with warning label facing out.

Replacement of Motor Starter

1. Remove Cover Plate and screws (#55 & #56). See pg. 20.
2. Disconnect wires, a) the red wires from the pressure
switch, b) the black wire from the motor and, c) the black
wire from the On/Off Switch.
3. Remove screws (#58) and washer and nuts (#52 #53).
4. Replace Motor Starter and re-secure with screws, washer
and nuts (#58, #53 and #52).  Always use heat sink material
on the back of the Motor Starter when installing.
5. Reconnect wires according to Figure 3A.
6. Reinstall switch cover and screws, with warning label
facing out.

Содержание Epic 447HPX

Страница 1: ...EADING THIS MANUAL Epic 660HPX Epic 660HPX 120V Pump Only 702 405 120V Complete 702 410 230V Pump Only 702 102 CE 230V Complete 702 104 CE This manual contains important warnings and instructions Plea...

Страница 2: ...spray systems against rust corrosion and premature wear Case of 12 1 quart bottles 700 888 1 quart 700 889 Table of Contents Accessories 2 General Repairs Service 3 Maintenance Service Record 4 Warni...

Страница 3: ...t operate properly review the repair procedure to determine if everything was done correctly Refer to the Troubleshooting Charts to help identify other possible problems 4 Make certain that the servic...

Страница 4: ...e needed to validate your warranty Electric Pump Maintenance Schedule Service Record Service Performed Date Service Center Cost of Repair Months in Service Service Performed Date Service Center Cost o...

Страница 5: ...escape wire for the electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed...

Страница 6: ...nchufe de puesta a tierra podr a crear el riesgo de choque el ctrico Si es necesario reparar o re emplazar el cord n o el enchufe no conecte el alambre de puesta a tierra a ninguna de las dos terminal...

Страница 7: ...cipient en m tal lors du rin age du syst me apr s en avoir t la buse Ne vaporisez JAMAIS de substances inflammables proximit de flammes nues lampes t moin ni d aucune source d allumage Rangez l int r...

Страница 8: ...an Tool Inc spray equipment includes aluminum or galvanized components and will be affected by Halogenated Hydrocarbon solvents DO NOT USE HALOGENATED HYDROCARBONS IN TITAN EQUIPMENT EXPLANATION OF TH...

Страница 9: ...me dangereux Des tincelles peuvent galement se produire lors de branchement ou d branchement d un cordon d alimentation lectrique ou lors de la mise en marche d un moteur au gaz De telles tincelles so...

Страница 10: ...enados SOLVANTS HALOG N S D FINITION Tout solvant hydrocarbure contenant l un des l ments suivants EXEMPLES liste incomplete Pour d terminer si vos solvants ou rev tements contiennent des solvants a h...

Страница 11: ...is used by the factory for testing and protection It is necessary to flush out with mineral spirits before you begin to spray A Pour 1 2 gallon mineral spirits into a metal container and insert syphon...

Страница 12: ...from ground to roof Do not attempt to spray if wind is excessive For corners and edges split the center of the spray pattern on the corner or edge and spray vertically so that both adjoining sections...

Страница 13: ...sprayer run itself dry Step 12 Check filter on pump and gun Clean or replace Step 13 Remove spray tip from solvent clean with a soft bristle brush and store in a dry place PROBABLE CAUSE 1 Inadequate...

Страница 14: ...Pump will not maintain pressure Not enough pressure Excessive surge at spray gun Paint leaks into oil cup PROBABLE CAUSE 1 Unit unplugged or circuit fuse blown 2 Pressure setting too low 3 Brushes on...

Страница 15: ...48 with a wrench 4 Remove the On Off Switch 49 5 Install a new Switch and reattach plate and rubber boot Tighten securely 6 Reconnect the four wires to the new On Off Switch 7 Reinstall Switch Cover...

Страница 16: ...mber 1 120 700 802 Cap Nut 2 121 700 801 1 4 Carriage Bolt 2 122 702 127 Main Frame Right 1 123 710 045 Pin Axle 2 124 710 058 Washer Axle 2 125 702 048 Wheel 2 126 702 087 Spacer 2 127 700 652 Bolt 4...

Страница 17: ...X Syphon Down Tube for use with the High Rider Frame Only Replacement Labels PART NO DESCRIPTION QTY 700 418 Front Plate 1 Front Cover Label 313 175 Warning Attention Label in French 1 313 1205 Wrapar...

Страница 18: ...follow all other warnings to reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1 Remove Rear Cover 131 by taking out screws...

Страница 19: ...s to reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1 Follow steps 1 through 6 in Armature Replacement 2 Remove Switch cov...

Страница 20: ...er Boot 1 48 700 775 On Off Plate 1 49 700 646 Toggle Switch 1 50 765 072 Wire Switch to Starter 1 51 700 895 Fuse 15 Amp 1 52 700 714 Nut 2 53 700 785 Lock Washer 3 54 700 657 Motor Starter 1 55 761...

Страница 21: ...f Procedure outlined on Page 5 Additionally follow all other warnings to reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1...

Страница 22: ...Ring 1 218 700 246 Bypass Housing 1 includes 216 217 219 700 721 005 O Ring 1 220 700 250 Bypass Valve Stem 1 222 700 244 Spring 1 224 700 248 Bypass Valve 1 Retainer 225 700 252 Bypass Cam Base 1 226...

Страница 23: ...and Bypass Cam 225 3 Using a wrench loosen Bypass Housing 218 and unscrew 4 Unscrew Bypass Retainer 224 and remove Bypass Valve Stem 220 5 Inspect ball on end of Stem 220 and O Ring 219 Clean or repl...

Страница 24: ...included 391 700 804 Gasket 1 392 490 109 Fitting 1 350 730 501 Fluid Section Complete 301 305 307 323 1 700 024 Optional Urethane O Ring 1 Syphon Assembly ITEM NO PART NO DESCRIPTION QTY 340 700 206...

Страница 25: ...2 to piston 308 and secure tightly with a wrench PACKING REPLACEMENT 13 Remove Outlet Mounting Bolt 263 from rear of pump As shown in Figure 8 page 22 14 Remove screws 306 with a 3 8 allen wrench and...

Страница 26: ...n Site Gallons Sprayed Tips Used Date Completed Quantity Sizes Job Name Foreman s Name Type of Coating Date Begun Site Gallons Sprayed Tips Used Date Completed Quantity Sizes Job Name Foreman s Name T...

Страница 27: ...igh rider frame 702 105 CE 660HPX Pump Complete With high rider frame 702 174 CE 660HPX Pump Only With low rider frame old syphon 100V EXPORT PUMPS 702 212 660HPX Pump Only With low rider frame 702 21...

Страница 28: ...UDED TO THE EXTENT PERMITTED BY LAW TITAN MAKES NO WARRANTY AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ACCESSORIES EQUIPMENT MATERIALS...

Отзывы: