Tion O2 Lite Скачать руководство пользователя страница 24

24

Compact Ventilation Unit

5.4.2 Connecting the device to the MagicAir system

To use the device with the MagicAir system, first connect the device to it. Only 

devices with the designated interface unit can be connected to Magic Air.

To connect the device to the MagicAir base station simultaneously press the [+] 

and [SET] buttons on the device panel and hold for 2 s. The LCD will blink during the 

connection process. After a successful connect, a single beep will sound. The connec-

tion process takes at most 30 s. In the case of a connection failure, a double warning 

beep is issued.

After  a  successful  connect,  the  MagicAir  logo  will  be  displayed  (section  5.3.1). 

Once the device is connected, the time adjustment is disabled from the panel (time 

settings are then taken from the MagicAir system).

5.4.3 Control modes

After connection to the MagicAir system you can use either manual or automatic 

operating mode. The automatic mode can be switched on using the designated mobile 

application MagicAir and via the web interface on the site magicair.tion.ru, by moving a 

slider.  In the automatic control mode, its icon is indicated on the LCD (section 5.3.1).

In the automatic mode you can control the maximum/minimum fan speed, switch 

the heater on/off and set the heating temperature. 

For manual adjustment of the fan speed, timer, environmental parameters (from 

control panel or remote control) first disable the automatic control mode. To do so 

press any button (except   ) either on the control panel, or on the remote control. The 

automatic control mark will disappear from the LCD display.

In the manual control mode you can turn the device on and off,  adjust the fan 

speed, select the air intake mode, switch heater on/off and set up heating temperature

Switching between manual and auto control modes is performed in the MagicAir 

mobile application using the corresponding slider.

6. GETTING STARTED

6.1 Unpacking and Visual Inspection

Remove the transportation packaging and examine the device carefully to make 

sure it has no damage caused by improper transportation or storage. If you notice any 

damage, consult the service center of your Vendor to decide whether it is safe to use 

the device.

If the temperature of the device housing before installation is below 10 °C (after 

storage or transportation in cold environment), first keep the device for 2 hours in a 

warm room inside the packing film to bring its temperature up to room conditions. 

Failure to do so can cause device failure, damage its plastic parts during installation or 

lead to condensate formation.

Содержание O2 Lite

Страница 1: ...USER MANUAL Compact Ventilation Unit Tion 2 Breezer...

Страница 2: ......

Страница 3: ...User manual Compact Ventilation Unit Tion 2 Breezer...

Страница 4: ......

Страница 5: ...LIST 7 3 SAFETY REQUIREMENTS 8 4 TECHNICAL PARAMETERS 8 5 SCHEMATIC DIAGRAM AND OPERATING PRINCIPLE 9 6 GETTING STARTED 24 7 MAINTENANCE 26 8 STORAGE TRANSPORTATION DISPOSAL 28 9 WARRANTY 29 ACCEPTAN...

Страница 6: ...fined parameters may vary depending on the particular set purchased installation and operating environment and filter configuration and condi tion The Manufacturer reserves the right to introduce nece...

Страница 7: ...ed for use in all regions especially in locations with unfa vorable environmental settings The Tion O2 Lite version is recommended for use in regions with warm climate see outdoor temperature applicab...

Страница 8: ...m the mains supply 6 The device should be unplugged from the power supply system prior to main tenance or scheduled servicing 7 The user is not authorized to perform any repairs or alterations to the...

Страница 9: ...14 x 454 x 163 Assigned lifetime years 5 5 5 5 5 Guarantee period years 1 1 1 1 1 Compatibility with MagicAir Yes No Yes No No Use of the Tion O2 Lite version at negative outside air temperatures may...

Страница 10: ...e device through the flap via a heat insulated channel If the device is turned off the flap closes the channel for outside air into the device The air cleaning is performed inside the casing The schem...

Страница 11: ...oncentrations even as high as 10 times above maximal permissible levels Strong unpleasant odors are removed as well The dust filtration performance remains at 80 90 level 5 3 Control and Indication Th...

Страница 12: ...fore filter replace ment Inlet air tempera ture Temperature of air at the out let Replace filters Fan speed Figure 3 LCD display elements Figure 4 LCD display when the device is under automated contro...

Страница 13: ...guration Figure 8 LCD display in standby mode section 5 3 4 5 3 2 Control Panel Buttons The command buttons are located on the control panel Fig 9 They are used for controlling the device switching be...

Страница 14: ...Power Switching between standby and active mode SET Selection of pa rameters Decrease value or deactivate Increase value or activate Figure 10 Remote control buttons Before first startup of the devic...

Страница 15: ...r via the MagicAir system it enters the Standby mode Fig 11 12 In the standby mode the device does not perform its operating functions the flap is closed the fan is off but the power is still connecte...

Страница 16: ...ntrol panel or remote control Pressing the or buttons decreases or increases the air flow if no other settings are being adjusted at the same time section 5 3 7 Air flow indication on LCD is show in F...

Страница 17: ...te Lite configuration If MagicAir is connected the parameter cannot be adjusted If the device is under control of MagicAir the parameter cannot be adjusted Available values of the parameter 25 30 35 4...

Страница 18: ...restart the device for normal operation it should be unplugged from the power supply and then turned on again a few seconds later If you are using the Tion 2 Lite version the device should be turned o...

Страница 19: ...the control panel or remote control if MagicAir section 5 4 is not connected The Current Time set point is used in the timer function section 5 3 11 To adjust the parameter select it with the SET but...

Страница 20: ...Figure 15 Adjustment of start time for the device Press the button to increment the hours value by 1 h and the button to in crement the minutes value by 5 min To adjust the stop time for timer based...

Страница 21: ...rom the user defined value down to zero The counter counts the time only when the device is on and operating flap is open and fan is blasting air in If the device is in standby mode or switched off us...

Страница 22: ...h the device off for a short period press the button on the control panel or remote control The fan will turn off and the flap will close If a fault occurs during flap closure flap remains open a doub...

Страница 23: ...to the mains supply turn on the power switch on the right side of the device 5 4 Functioning with MagicAir 5 4 1 About the MagicAir System The MagicAir base station monitors the CO2 level in a room u...

Страница 24: ...control the maximum minimum fan speed switch the heater on off and set the heating temperature For manual adjustment of the fan speed timer environmental parameters from control panel or remote contr...

Страница 25: ...nance panel and make sure that both right and left latches are clamped shut Figure 18 Filter preparation workflow PLEASE NOTE Avoid applying force to the latches during panel reinstallation as this ma...

Страница 26: ...ufacturer s certi fied installation experts 4 Please pay careful attention to the correct installation of the device which is cru cial for ensuring both its proper operation and for the warranty oblig...

Страница 27: ...ing the switch button on the side panel and pull out the power cord from the socket 2 Remove maintenance panel Press on the left and right latches towards each other releasing the panel bot tom corner...

Страница 28: ...rror code is displayed disconnect the device from power supply for several seconds and turn it on again If the indication persists please contact the Ser vice Center Please note If turning the device...

Страница 29: ...period starts from the device manufacture date in accordance with consumer protection legislation The warranty terms cover manufacturing or design defects of the device The warranty obligations includ...

Страница 30: ...ran ty conditions imposed by current legislation in the case of detected device defects due to Manufacturer s fault Tion Smart Microclimate JSC reserves the right to deny of war ranty terms should the...

Страница 31: ...31 ACCEPTANCE CERTIFICATE Compact ventilation unit Tion 2 Breezer Corresponds to Technical Specifications TU 3646 001 66248641 2015 and is ac ceptable for operation Manufacturing date QC stamp...

Страница 32: ...C Standard MAC Base Base Lite please underline Serial number to be entered at purchase Vendor Sale date 20 Vendor s signature and stamp Version 1 6 2 WARNING The SALES CERTIFICATE field must be duly f...

Страница 33: ...33 FOR NOTES...

Страница 34: ...34 Compact Ventilation Unit FOR NOTES...

Страница 35: ......

Страница 36: ...tion global...

Отзывы: