19
on the display instead of «– –» dashes, and a single beep will sound. A single beep is
issued.
PLEASE NOTE!
• It is not recommended to turn off the heater if the inlet air temperature
is below 0°С, as this can cause frosting up of the device, resulting in
decreased performance and greater noise.
• Under increased humidity conditions in the room, for a certain range
of outlet air temperatures, condensate may accumulate on the external
surfaces of the device. In this case, turn on the heater and, if necessary,
increase the target temperature to 10 °С.
* A heater is not installed in Tion О2 Lite Lite configuration.
5.3.10 Current Time
Time adjustment can be performed manually (using the control panel or remote
control), if MagicAir (section 5.4) is not connected.
The «Current Time» set point is used in the timer function (section 5.3.11)
To adjust the parameter select it with the [SET] button (section 5.3.7).
Press the [-] button to increment the hours value by +1 h and the [+] button to incre-
ment the minutes value by +1 min.
If maximal time value is attained (23 h or 59 minutes), then subsequent pressing of
the button will cycle the value back to the minimum (00 h or 00 min.)
5.3.11 Timer
The timer is used for turning the device on and off (switching to/from the standby
mode) at a predefined moment.
The timer can be configured from the control panel or remote control, only if the
device is not under automated MagicAir control. If the device is controlled by MagicAir,
all previous timer setting become inactive.
Blinking segment
Figure 14. Timer mode indication
Содержание O2 Lite
Страница 1: ...USER MANUAL Compact Ventilation Unit Tion 2 Breezer...
Страница 2: ......
Страница 3: ...User manual Compact Ventilation Unit Tion 2 Breezer...
Страница 4: ......
Страница 33: ...33 FOR NOTES...
Страница 34: ...34 Compact Ventilation Unit FOR NOTES...
Страница 35: ......
Страница 36: ...tion global...