17
To select a system parameter to be changed, press the [SET] button. Switching
between the parameters is also achieved by sequential pressing of the [SET] button.
When selecting a parameter, its icon on the LCD display will start blinking.
If the parameter value can be set, then one pressing of the [-] or [+] button changes
the value by one unit of measurement. To change the parameter value by several units,
press and hold the [-] or [+] button for more than 1 s until you reach the desired value.
No.
Adjusted parameter
Button functions
1
Target air temperature*
[-]: -1°С, [+]: +1°С
Heater*
[-] and [+] for 2 s: on/off
2
Current time**
[-]: +1 hr, [+]: +1 min
3
Timer on/off***
[+] or [-]: on/off
4
Timer value for device launch***
[-]: +1 hr, [+]: +5 min
5
Timer value for device stop***
[-]: +1 hr, [+]: +5 min
6
Minimal admissible inlet air
temperature****
[+]: next value, [-]: previous value
7
Filter Service Interval
[+]: +30 days, [-]: -30 days; [-] and [+] for 2
s: 360 days
* A heater is not installed in Tion О2 Lite Lite configuration.
** If MagicAir is connected, the parameter cannot be adjusted.
*** If the device is under control of MagicAir, the parameter cannot be adjusted.
**** Available values of the parameter: -25°С, -30°С, -35°С, -40°С.
The target temperature and fan speed have limiting values, which cannot be
looped: after the maximal value is reached, further pressing of the [+] button will not
cyclically bring the parameter back to its minimal value; instead the maximal value
will be kept. All other parameters are looped, which means that after their maximal
values are reached further pressing of the [+] button will cycle the parameter back to
its minimum.
To accept and save the settings and move to another parameter, do one of the
following:
•
press and hold for 2 s the [SET] button (this action is not available from the RC),
•
do not press any other buttons for 10 s.
A single beep will sound, confirming the changes have been saved and updated.
Simultaneously pressing 4 buttons: [SET], [-], [+] and (not available from the
RC) will reset all user settings to factory defaults. This function is not active when a
parameter is being set.
Содержание O2 Lite
Страница 1: ...USER MANUAL Compact Ventilation Unit Tion 2 Breezer...
Страница 2: ......
Страница 3: ...User manual Compact Ventilation Unit Tion 2 Breezer...
Страница 4: ......
Страница 33: ...33 FOR NOTES...
Страница 34: ...34 Compact Ventilation Unit FOR NOTES...
Страница 35: ......
Страница 36: ...tion global...