Compact Ventilation Unit
•
pressing the button on the remote control;
•
timer-driven switching on/off,
•
automatic switching on/off with the MagicAir system (section 5.4).
Device activation (switching from standby to active mode) is accompanied by a
single beep, device deactivation by a double beep (in manual control mode, if sound
signals are enabled). All user configured values are retained upon switching between
modes.
If the device was in active mode before being disengaged using the switch button
on the device side panel or by disengagement from the power supply, its re-engage-
ment will bring it into standby mode.
5.3.6 Air Flow Settings
Four air flow rate steps are provided. The air flow rate is adjusted manually (using
control panel or remote control) or automatically with the MagicAir system (section
5.4).
In manual mode the adjustment is performed with the [-] and [+] buttons on the
control panel or remote control.
Pressing the [-] or [+] buttons decreases or increases the air flow, if no other settings
are being adjusted at the same time (section 5.3.7).
Air flow indication on LCD is show in Fig. 13.
first speed
second speed
third speed
«turbo» speed
Figure 13. Air flow rate indication
The «turbo» mode is used for enhanced, rapid aeration in a room after a longer
period of not being used by people.
Under low outside air temperatures, the device may automatically decrease the fan
speed to ensure proper air heating and optimal energy consumption. Consequently,
there will be less than four available flow rate steps. Should this happen, any attempt to
boost the fan speed will result in a double beep, the LCD display will signal the unavail-
ability of this function by means of blinking active elements of air flow indication. All fan
speeds will remain available if heater mode is off.
5.3.7 Settings configuration with the [SET], [-] and [+]
buttons
The device settings are adjusted manually (using the control panel or remote con-
trol) or automatically with the MagicAir system (section 5.4).
Содержание O2 Lite
Страница 1: ...USER MANUAL Compact Ventilation Unit Tion 2 Breezer...
Страница 2: ......
Страница 3: ...User manual Compact Ventilation Unit Tion 2 Breezer...
Страница 4: ......
Страница 33: ...33 FOR NOTES...
Страница 34: ...34 Compact Ventilation Unit FOR NOTES...
Страница 35: ......
Страница 36: ...tion global...