5.3.8 Setting the air heating target temperature
The target temperature* of the outlet air is adjusted in manual mode (using control
panel or remote control) or automatically with the MagicAir system (section 5.4).
Target temperature adjustment range: from -20°С to +25°С. The new target tem-
perature is attained in 1-5 minutes.
Factory setting: +20°C.
Press the [SET] button; the target value on the LCD display will start blinking. Using
the [-] or [+] buttons select the required target temperature. If the heater is off (section
5.3.9), neither of the buttons [-] or [+] will have any effect.
PLEASE NOTE!
• If the inlet air temperature is above the target value (no heating is
needed), the target temperature is not displayed. To review the set
temperature, press the [SET] button.
• If the ambient air temperature decreases below its minimum value,
specified by the «minimum admissible temperature» parameter (section
5.3.12), the device will automatically shut down. The warning message
«ЕС02» will be displayed (section 7.2), and the flap will close. Should this
happen, to restart the device for normal operation it should be unplugged
from the power supply and then turned on again a few seconds later.
• If you are using the Tion О2 Lite version, the device should be turned
off in the case of condensate or frost formation. It is recommended
to resume operation only after its temperature warms up to the room
temperature and traces of frosting disappear. To prevent frosting and
condensate formation in the future, contact any authorized Service
Center of the Manufacturer to upgrade the installation with a heater
system (at additional cost).
* A heater is not installed in Tion О2 Lite configuration.
5.3.9 Switching heater off
The heater* can be turned off manually using the control panel.
To turn off the heater, press the [SET] button to go to target temperature adjustment
(section 5.3.7). Press simultaneously and hold for 2 s the [+] and [-] buttons (option is
unavailable from the RC). The «HEATER OFF» warning will be displayed and a single
sound beep will be issued. Instead of target temperature value, blinking «- -» dashes will
be displayed, and target temperature adjustment will be disabled. In the operating mode
the target temperature is not indicated.
To turn the heater on, repeat the same actions. The target temperature will be shown
Содержание O2 Lite
Страница 1: ...USER MANUAL Compact Ventilation Unit Tion 2 Breezer...
Страница 2: ......
Страница 3: ...User manual Compact Ventilation Unit Tion 2 Breezer...
Страница 4: ......
Страница 33: ...33 FOR NOTES...
Страница 34: ...34 Compact Ventilation Unit FOR NOTES...
Страница 35: ......
Страница 36: ...tion global...