C190-0308 - Rev 1.0 EN
25/66
Engine Stop Switch
Pushing the Engine Stop Switch on top of the engine bay will cause the engine to run
down and stop in the shortest possible time from its current operating status.
The engine cannot be restarted until the Engine Stop Switch is reset and the main
ignition switch is turned off to reset the machine.
N.B. The feed rollers will NOT stop immediately, but will stop as the engine falls below
the pre-set ‘No Stress’ speed (See Section 4.2 "
No Stress Control" on page 24).
Emergency Stop Button (Timberwolf Safety Plus Kit Only)
Pushing any one of the Emergency Stop Buttons on the top of the funnel, or either side
of the feed tray, will remove all power to the engine AND the feed rollers, bringing the
whole machine to a complete stop.
The engine cannot be restarted until the operated Emergency Stop Button is reset and
the main ignition switch is turned off to reset the machine.
4.4
Discharge Controls
Controlling the direction and angle of the discharge is an essential part of operating the
chipper in a safe manner.
Discharge Direction
1.
Slacken the locking nut using the integral handle (Figure 5).
2.
Rotate the discharge tube to face in a safe direction.
3.
Re-tighten the locking nut.
Discharge Angle
Use the handle to adjust the bucket to achieve a safe discharge angle (Figure 6).
Figure 5 - Discharge Tube Locking Nut
Figure 6 - Discharge Bucket
4 Operating Instructions
TW 280FTR (Petrol)
Содержание TW 280FTR (Petrol)
Страница 1: ...C190 0308 Rev 1 0 EN TW 280FTR Petrol Wood Chipper INSTRUCTION MANUAL Original Instructions...
Страница 6: ...4 66 C190 0308 Rev 1 0 EN TW 280FTR Petrol THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 24: ...22 66 C190 0308 Rev 1 0 EN TW 280FTR Petrol THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 56: ...54 66 C190 0308 Rev 1 0 EN TW 280FTR Petrol THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 57: ...C190 0308 Rev 1 0 EN 55 66 6 Electrical System 6 Electrical System TW 280FTR Petrol...
Страница 58: ...56 66 C190 0308 Rev 1 0 EN TW 280FTR Petrol 6 Electrical System...
Страница 59: ...C190 0308 Rev 1 0 EN 57 66 7 Hydraulic System 7 Hydraulic System TW 280FTR Petrol...
Страница 60: ...58 66 C190 0308 Rev 1 0 EN TW 280FTR Petrol THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 64: ...62 66 C190 0308 Rev 1 0 EN TW 280FTR Petrol THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 66: ...9 Declaration of Conformity 64 66 C190 0308 Rev 1 0 EN TW 280FTR Petrol 9 Declaration of Conformity...
Страница 67: ...C190 0308 Rev 1 0 EN 65 66 10 Notes 10 Notes TW 280FTR Petrol...
Страница 68: ...C190 0308 Rev 1 0 EN...