13
EN
Water from the heater that is installed vertically on the wall
can be drained through the heater's inlet pipe. For this purpose
it is advisable to install a T
-
element with an outlet valve
between the inlet pipe and safety valve.
A heater installed horizontally on a wall can only be emptied by
an authorised service provider.
Please do not try to fix any defects of the water heater on
your own. Call the nearest authorised service provider.
Our products incorporate components that are both environmentally safe
and harmless to health, so they can be disassembled as easily as possible
and recycled once they reach their final life stage.
Recycling of materials reduces the quantity of waste and the need for
production of raw materials (e.g. metals) which requires a substantial
amount of energy and causes release of harmful substances. Recycling procedures
reduce the consumption of natural resources, as the waste parts made of plastic and
metal can be returned to various production processes.
For more information on waste disposal, please visit your waste collection centre or
the store where the product was purchased.
Dear buyer, thank you for purchasing our product.
Prior to the installation and first use of the electric water heater, please
read these instructions carefully.
This water heater has been manufactured in compliance with the relevant standards
and tested by the relevant authorities as indicated by the Safety Certificate and the
Electromagnetic Compatibility Certificate. Its technical characteristics are indicated on
the label on the bottom of the heater next to the pipes. The installation must be
carried out by qualified staff. All repairs and maintenance work within the water
heater, e.g. lime removal or inspection/replacement of the protective anticorrosion
anode, must be carried out by an authorised maintenance service provider.
INSTALLATION
The water heater shall be installed as close as possible to the outlets. When installing
the water heater in a room with a bathtub or shower, take into account the
requirements defined in IEC Standard 60364
-
7
-
701 (VDE 0100, Part 701). It has to
be fitted to the wall using appropriate wall screws with a minimum diameter of 8 mm.
A wall with a poor load
-
bearing capacity must be properly reinforced where the heater
will be installed. The FTG 30 E5 heater may only be mounted vertically on the wall
while the other heaters can be installed vertically as well as horizontally, provided that
the connection fittings are facing to the left. To facilitate future service interventions,
you are advised to install the heater in accordance with the installation
measurements (see Fig. 1 and Fig. 2).