consumption habits (e.g. showering every day at approximately the same time). To
start the heater in the "
Eco
Smart" mode, you first have to start recording. During the
recording time, the electronic regulator remembers your habits and takes them into
account while heating the water after the recording period has ended. The recording
takes place for 7 days. The "
Eco
Smart" mode reduces the consumption of electrical
energy.
•
Pressing button no. will begin the recording of your habits. The green control
light will flash during the recording period. Once recording concludes after 7
days, the recording regime will begin running automatically. The green control light
will light up when the heater is functioning in the "
Eco
Smart" mode.
•
By pressing again, you can switch off the recording or the "
Eco
Smart" function.
The heater resumes to the basic mode of operation. The water is heated to the set
temperature.
•
The "
Eco
Smart" function can be resumed by pressing button no. . If the regime
has already been recorded (if the recording was not interrupted), the regime will
begin running and the green control light will light up. If the recording was
interrupted, a new 7
-
day recording period will begin and the green control light
will again begin flashing.
•
If the electronic regulator has recorded the regime but the user's hot water
consumption habits have changed, a new recording period must be started. It can
be started by holding button no. . The recording period lasts 7 days.
The Anti
-
Legionella Function
If the water in the heater does not reach 65 °C for 14 consecutive days, the anti
-
legionella function heats the water to 70 °C and maintains this temperature for 120
minutes.
Indication of errors
In case of error, control lights start to flash on the display .
Emptying the heater
If you are planning to unplug the heater from power supply, please drain out all the
water to prevent freezing. Water from the heater that is installed vertically on the wall
can be drained through the heater's inlet pipe. For this purpose it is advisable to
Error
Error description
Signalization
Solution
E1
Temperature sensor
error
Repeated 2x quick pulse
of the control light on the
display .
Call service (heater out of order).
E5
Overheating
(temperature > 90 °C)
Repeated 3x quick pulse
of the control light on the
display .
The error is automatically deleted
when the temperature drops
below the set value. Should the
error repeat, please call the
service company.
E44
Dry start
Repeated 4x quick pulse
of the control light on the
display .
Fill the heater with water. The
error is deleted by switching off
the heater or by holding button
for 3 seconds.