50
HA0364T Rev C Aug 2022
Chapter 6
motor actuator will accelerate and move at the jog velocity while the button is held
down..
Fig. 6.3 Jog Modes
Single Step
- the motor moves by the step size specified in the Step Distance
parameter.
Continuous
- the motor continues to move until the jog signal is removed (i.e. jog
button is released).
Stopping
- the way in which the jog motion stops when the demand is removed.
Immediate
- the motor stops quickly, in a non-profiled manner
Profiled
- the motor stops in a profiled manner using the jog Velocity Profile
parameters set above.
Step Distance
- The distance to move when a jog command is initiated. The step size
is specified in real world units (mm).
distance
velocity
distance
velocity
button
pressed
button
pressed
button
pressed
button released
jog step size
jog velocity
jog velocity
Single Step mode
Continuous mode
jog acceleration