BC207 Series
Chapter 5: The Graphics User Interface (GUI)
Page 53
MTN026962-D02
The amplitude of the Gaussian fit curve may be lower or even higher than the peak intensity of
the measured curve.
The selected clip level (default 13.5%) is displayed if the "Auto Scale to Peak" function is en-
abled (button
).
The horizontal scale is displayed in pixels or µm and its range refers to the selected
. The unit of the scale can be changed in the
dialog.
Toolbar
Icon
Associated Action
Opens a dialog box to specify the properties of the saved screenshots / dia-
grams.
Opens a dialog box to save measurement data to XLS or CSV file.
Toggle button to display grid in the diagram. Default: grid is shown.
Zoom Home button
Cursor mode - toggle button to show or hide the cursor.
Show / Hide calculation area
Cursor Mode
Move the mouse pointer close to the vertical cursor line. The mouse pointer
changes to
. The cursor line can be moved with the left mouse button
pressed to a position inside the diagram. The current values at the cursor po-
sition are shown in a rectangle next to the cursor in the colors of the plotted
curve.
5.6.4 Zooming and Panning Diagrams
All diagrams, e.g. X and Y profiles, plot diagrams, M² and divergence diagrams, that have a
slider, can be manipulated for X and Y scale (zoom) as well as for X and Y positioning (pan).
Zoom Mode
To zoom in the diagram, draw a rectangle with the left mouse button pressed. Right click the
diagram to revert to the last zoom action.
Zoom Home button returns to display of the complete diagram.
Zooming the Diagram Axes
Move the mouse cursor over an edge of the vertical or horizontal scroll bar slider.
The cursor changes to
ô
or
ó
. Press and hold left mouse button and move the
mouse. This will zoom in on the appropriate part of the diagram axis. Return to
default view using the Zoom Home button.
Panning the Diagram Axes
Move the mouse pointer over the center of the vertical or horizontal scroll bar
slider and press left mouse button. Now the slider can be moved to pan (shift)
across the diagram. Return to default view using the Zoom Home button.
38
44
Содержание BC207UV
Страница 2: ...Copyright 2022 Thorlabs Version Date 8 1 10 Jan 2022 ...
Страница 103: ...BC207 Series Chapter 6 Operation Instructions Rev 8 1 10 Jan 2022 Page 96 2022 Thorlabs ...
Страница 133: ...BC207 Series Chapter 6 Operation Instructions Rev 8 1 10 Jan 2022 Page 126 2022 Thorlabs ...
Страница 175: ...BC207 Series Chapter 10 Appendix Rev 8 1 10 Jan 2022 Page 168 2022 Thorlabs 10 11 Certifications and Compliances ...
Страница 181: ...www thorlabs com ...