BC207 Series
Chapter 10: Appendix
Rev: 8.1, 10-Jan-2022
Page 160
© 2022 Thorlabs
Item #
BC207UV(/M)
BC207VIS(/M)
Image Capture Modes
Single Frame, Continuous, Hardware Triggered
Sensor Distance to Front (Filter
Holder Surface)
20.7 mm (0.82")
Interfaces
Trigger Input
TTL Level, LVTTL compatible, BNC Jack,
Low: 0 to +0.5 V
High: 2.4 V to 5.5. V
, BNC Jack
10)
Trigger Delay
0.27 µs
Pulse Width (Min)
100 µs
PC Interface
USB 3.0 (Micro B)
Item #
BC207UV(/M) and BC207VIS(/M)
General
Operating Temperature
10 °C to 35 °C
Storage Temperature
0 °C to 55 °C
Size (H x W x D) Including Filter Wheel
94.3 mm x 84.8 mm x 85.7 mm
(3.71'' x 3.34'' x 3.37'')
Weight
420 g
Mounting Holes, Imperial Version
1/4''-20
Mounting Holes, Metric Version
M6 x 1 mm
Power Supply
3.6 W, USB Bus Powered
All technical data are valid at 23 ± 5°C and 45 ± 15% rel. humidity.
1)
The wavelength range of the supplied UV ND filters starts at 200 nm, see chapters
2)
@ 400 nm depending on beam diameter and ND filter.
3)
The neutral density filter will begin to heat up and can be damaged if exposed to incident powers above 1 W for
more than a few seconds.
4)
@ 700 nm depending on beam diameter and ND filter.
5)
Damage threshold data is currently not available for the BC207 beam profilers. For applications with pulsed
lasers, we recommend the following procedure as a guideline for determining a safe upper limit: Set the beam
profiler to the maximum integration time (i.e., set the exposure to 1 s). Slowly increase the power until your signal
reaches approximately 50% of the intensity as shown in the profile window of the Beam Software package. Mul-
tiply this power by a factor of 10. This is the safe upper limit of the mean pulse power for the beam profiler.
6)
These filters are provided for use near the 400 nm upper wavelength range of the BC207UV(/M). See the chapter
for more information.
7)
One set of filters is AR coated for the 350 nm to 700 nm range while the other is AR coated for the 650 nm to the
1050 nm range. See the chapter
for more information.
8)
Highly dependent on PC processor, graphic adapter performance, and size of calculation area.
9)
In Multi Pulse Detection, single pulses are not distinguished.
10)
See chapter
for detailed data.
5
162
162
7
Содержание BC207UV
Страница 2: ...Copyright 2022 Thorlabs Version Date 8 1 10 Jan 2022 ...
Страница 103: ...BC207 Series Chapter 6 Operation Instructions Rev 8 1 10 Jan 2022 Page 96 2022 Thorlabs ...
Страница 133: ...BC207 Series Chapter 6 Operation Instructions Rev 8 1 10 Jan 2022 Page 126 2022 Thorlabs ...
Страница 175: ...BC207 Series Chapter 10 Appendix Rev 8 1 10 Jan 2022 Page 168 2022 Thorlabs 10 11 Certifications and Compliances ...
Страница 181: ...www thorlabs com ...