9
Automatic Heat-up:
This function allows rapid heat up of the induction zone,
with automatic reduction to a preset level once the desired temperature is
reached. To activate, with a suitable pan in position and the control set to ‘0’,
rotate the control knob anti-clockwise briefly until ‘A’ is shown in the LED display,
then rotate the knob immediately clockwise to the desired pre-set power level.
The LED indicator shows ‘A’ and the induction unit will operate on maximum
power setting to bring the cooking zone up to temperature. The unit then
automatically reduces the power to the pre-set level which is then displayed. The
Automatic Heat-up function operates in accordance with the times shown in the
table below.
Power Level
Auto Heat-up Time at
100% power in min:sec
1
0:40
2
1:10
3
2:00
4
2:53
5
4:13
6
7:10
7
2:00
8
3:08
9
N/A
Automatic Safety Cut-Off:
The maximum operating time for the heater is
automatically limited, depending on the power setting used in accordance with
the table below.
Power Level
Maximum Operating
Time in Minutes
1
520
2
402
3
318
4
260
5
212
6
170
7
139
8
110
9
90
Once the maximum operating time for any power level is exceeded, the heater is
automatically switched off and the LED indicator goes blank, indicating that the
control must be set to ‘0’ power setting to reset the system.
Содержание SHB981 Series
Страница 22: ...22 Fig 6 Mains Wiring Diagram...