18
INSTALLATION
Electrical Connection
Models fitted with power cord only (See Fig.6 Mains Wiring Diagram).
These appliances are supplied with a double insulated cord, type 227 IEC 53,
HO5V V-F, which is suitable for use up to 10 amps. This should be connected to
a suitable double pole switched mains supply, with 3mm minimum contact
separation at all poles. Ensure that all electrical cables and wires are routed well
clear of any heat source, including this appliance. Do not allow the cord to hang
loose into the lower compartment. The switch must be accessible after
installation.
Models fitted with plug and power cord
These appliances are supplied with a plug attached to the end of the power cord,
for connection to a switched wall mounted socket. After connection ensure the
power cord and any other electrical wires are routed well clear of any heat
source, including this appliance. Do not allow the cord to hang loose into the
lower compartment. The switched socket must be accessible after installation.
Induction Functions
The induction heater has a rotary control knob with 9 positions, from 0 = off to 9 =
high setting. High setting is automatically limited to a maximum of 90 minutes
continuous use and there is an LED indication of power on and residual heat.
Pan detection for induction heater – after 30 seconds without a pan or with an
unsuitable type of pan, the heater switches off automatically and will not reset
without the control switch first being returned to zero.
After connection, test for electrical safety. Refer to the User Instructions
and warnings enclosed and test all induction heating functions described.
Electrical Connection – 12V DC Spark Ignition
The spark ignition generator must only be connected to a suitable 12V DC
supply, e.g 12V vehicle battery. Transformers if used must be of the fixed voltage
type. Use sheathed spade connectors to connect the spark generator to the
power supply.
After installation and connection this appliance must be tested for gas
soundness, ignition of all burners including simultaneous ignition and electrical
safety. The gas supply pressure to which this appliance is connected must not
rise or fall by more than 2.5 mbar from the stated nominal, when all appliances
connected to the supply are operated simultaneously.
In the event that this appliance cannot be adjusted to perform correctly and for
any service assistance, please contact your authorised Thetford Service Agent
giving details of the model and serial number from the data badge on the
underside of the appliance, plus the date of purchase.