background image

ThermoControl Temperature Controller  

Electronic temperature controller with timer (clock controller) for flush mounting and for smart 
function (this function sets the time at which the comfort temperature should be reached) 
 

Universal controller

 HRT 6015-50 for optional 

use as     
      

     Floor temperature controller 10 to 60 °C, 
 
     Room temperature controller 5 to 30 °C 

 
     Room temperature controller 5 to 30 °C  

     with floor temperature monitoring 
     

Room temperature controller 5 to 30 °C 

 

Floor temperature controller 10 to 40 °C 

 

 

 
The room temperature contr

ollers can also be used as cooling controllers (see “Commissio

n

ing”).

 

 
Smart operation is activated on all controller types. 
Also available as master controller (option) for connecting clockless bi-metal and/or electrical controllers as 
satellites. 

 
Device view 

Figure 1 

 

Содержание HRT 6015-50

Страница 1: ...ntroller 10 to 60 C Room temperature controller 5 to 30 C Room temperature controller 5 to 30 C with floor temperature monitoring Room temperature controller 5 to 30 C Floor temperature controller 10...

Страница 2: ...floor or convectors supplementary heating for floor background heating in bathrooms electrical perimeter heating or warm water heating with control valves The controlled variable is either the room te...

Страница 3: ...duit box When using additional intermediate terminals the use of a deep conduit box is recommended Mounting height Approx 1 5 m above floor Avoid exposure to water When used as a room temperature cont...

Страница 4: ...tion Figure 3 and 4 L N PE T A F F NL 1NL Heating NTC 230V mains supply Floor temperature sensor Master output optional L N PE TA F F NL 1N L NTC 230V mains Floor temperature sensor Heating mat Master...

Страница 5: ...ler 10 to 60 C For changes see Changing controller options If you have moved a jumper or changed the rotary switch setting on the universal controller the Reset button must be pressed after the und co...

Страница 6: ...constant by the controller At the other times the device regulates the temperature to the setback temperature value i e the heating is switched back on if it goes below the defined setback temperatur...

Страница 7: ...on the display Hold down the C button and press the button You can now release the C button and set the time with the or buttons Holding the button down for a long time first changes the setting slowl...

Страница 8: ...ashing quickly by pressing the or button Change the bar by pressing the C button The next bar will then flash and can likewise be changed In this way all the bars can be switched from setback to heati...

Страница 9: ...am is changed Turn the adjustment dial back to the required heating temperature and if necessary move up the slide switch to the clock position Min set back temperature on floor temperature controller...

Страница 10: ...a controller option is changed The change is activated automatically after approx 60 to 90 secs If necessary reset the personal E user program and the set back temperature Reset button Pressing the Re...

Страница 11: ...ellites The TA output can be used to connect virtually any number of clockless temperature controllers e g commercially available bimetal controllers with their L set back input TA as satellites If th...

Страница 12: ...Reservation of right Subject to technical modifications Compensation cannot be claimed on account of modifications errors or print errors...