Safety instructions 

Only authorised electricians are permitted to work on a 230 V mains voltage. The safety regulations 

of the VDE and the local electrical utility company must be observed 
The connection work stated in these instructions must not be carried out when the mains voltage is 

switched on. 
A 30 mA residual current circuit-breaker must be used in humid areas (such as bathrooms) in 
accordance with VDE 0100. 

The mains supply must be protected by means of a miniature circuit-breaker (16 A). 
A terminal cross-section of 2.5 mm

 must be used for a heating output of 3 kW or higher. 

 

Description/application range 

The electronic temperature controller with timer control is designed for controlling the floor 
temperature and/or the room temperature in individual rooms. 

 
It can be used, for example, for electrical direct heating (floor or convectors), supplementary heating 
for floor background heating in bathrooms, electrical perimeter heating or warm water heating with 

control  valves.  The  controlled  variable  is  either  the  room  temperature  using  an  integrated  room 
temperature sensor or the floor temperature using the supplied floor temperature sensor at the level 

of the heating mat.  
AC 230V 

normally closed

 control valves are used for the control of warm water heating systems.  

 

Technical data 

Colour   

 

 

alpine white 

Degree of protection 

 

IP 30 

Protection class   

 

II 

Mains voltage 

 

 

230 V 

 +/- 10%, 50 Hz 

Room controller versions 

 

5 to 30 °C  

Floor controller version 

 

10 to 40 °C  

Max. switching current  

 

12 (4 ) A floor controller 

Max. switching capacity 

 

2.7 kW floor controller  

 

Switch temperature differential 

0.7 K 

Switch contact 

 

 

Opens on overtemperature 

Temperature sensor 

 

NTC to DIN 44574 

Temperature sensor cable   

4 m length, max.

 

 8 mm  

Directives/Standards/Approvals 

EMC Directive 89/336/EEC 

 

 

 

 

EU Low-Voltage Directive 73/23/EEC 

Ambient temperature 

 

-10 to + 40 °C  

Energy class 

 

IV = 2.0% 

Содержание HRT 6015-50

Страница 1: ...ntroller 10 to 60 C Room temperature controller 5 to 30 C Room temperature controller 5 to 30 C with floor temperature monitoring Room temperature controller 5 to 30 C Floor temperature controller 10...

Страница 2: ...floor or convectors supplementary heating for floor background heating in bathrooms electrical perimeter heating or warm water heating with control valves The controlled variable is either the room te...

Страница 3: ...duit box When using additional intermediate terminals the use of a deep conduit box is recommended Mounting height Approx 1 5 m above floor Avoid exposure to water When used as a room temperature cont...

Страница 4: ...tion Figure 3 and 4 L N PE T A F F NL 1NL Heating NTC 230V mains supply Floor temperature sensor Master output optional L N PE TA F F NL 1N L NTC 230V mains Floor temperature sensor Heating mat Master...

Страница 5: ...ler 10 to 60 C For changes see Changing controller options If you have moved a jumper or changed the rotary switch setting on the universal controller the Reset button must be pressed after the und co...

Страница 6: ...constant by the controller At the other times the device regulates the temperature to the setback temperature value i e the heating is switched back on if it goes below the defined setback temperatur...

Страница 7: ...on the display Hold down the C button and press the button You can now release the C button and set the time with the or buttons Holding the button down for a long time first changes the setting slowl...

Страница 8: ...ashing quickly by pressing the or button Change the bar by pressing the C button The next bar will then flash and can likewise be changed In this way all the bars can be switched from setback to heati...

Страница 9: ...am is changed Turn the adjustment dial back to the required heating temperature and if necessary move up the slide switch to the clock position Min set back temperature on floor temperature controller...

Страница 10: ...a controller option is changed The change is activated automatically after approx 60 to 90 secs If necessary reset the personal E user program and the set back temperature Reset button Pressing the Re...

Страница 11: ...ellites The TA output can be used to connect virtually any number of clockless temperature controllers e g commercially available bimetal controllers with their L set back input TA as satellites If th...

Страница 12: ...Reservation of right Subject to technical modifications Compensation cannot be claimed on account of modifications errors or print errors...

Отзывы: