Programming
Changing the setback temperature
(default setting 15 °C)
Set the
switch to the Sun symbol (all bars are now long on the display).
Set the new setback temperature required with the adjustment dial (see Figure 1).
Hold down the + button and press the
–
button once.
The new setback temperature is now saved and is shown briefly on the display for control purposes.
It is retained when the program is changed.
Turn the adjustment dial back to the required heating temperature and if necessary move up the slide
switch to the clock position.
Min. set-back temperature on floor temperature controller: 10 °C
Min. set-back temperature on room temperature controller: 5 °C
Changing the controller options of the universal controller
Figure 6
Figure 7
Step 4:
Set the required controller option here
J1 (Jumper)
Heating / cooling
J2 (Jumper)
Smart mode
-
+
C
~
~
~
1
2
5
4
3
2
0
4
6
8
10
12
12
16
20
22
24
18
14
Step 3: remove cover
Step 1: carefully remove adjustment dial
with a small screwdriver
Set 2: undo screw