Figure 5
Commissioning
If a room temperature controller is to be used as a cooling controller, remove jumper 1 (figure 7) with
a long nose pliers and fit it in the two upper sockets. To deactivate the smart function remove jumper
2 (figure 7) and fit it into the two sockets on the right.
The universal controller is factory set as a floor temperature controller (10 to 60°C).
For changes see “Changing controller options”. If you have moved a jumper or changed the rotary
switch setting on the universal controller, the Reset button must be pressed after the und cover is
fitted and the mains voltage is switched on.
Then set the Heating On/Off switch on the controller to the
position (Figure 1). Setting the time and weekday (see “Progra
m
ming”)
Move the
switch to the required position.
= Continuous operation (heating system controls a constant heating temperature)
= Timed operation, the preset heating program no. 1 is now active.