2-6
2.3.2 Connecting Incoming Power 100/230 VAC (+/-10%)
To connect incoming power use the following procedure.
•
For input power use cable 14AWG
•
Wire the safety ground terminal locate on the backside of the enclosure (Protection GND PE).
•
Wire the HOT to terminal labelled of Terminal L on the Power Input Terminal.
Wire the NEUTRAL to the terminal labeled of Terminal N on the Power Input Terminal.
2.3.3 Connecting Incoming Power 24VDC (ON REQUEST)
To connect incoming power use the following procedure.
•
For input power use cable 14AWG
•
Wire the safety ground terminal locate on the backside of the enclosure (Protection GND PE).
•
Wire the POSITIVE (+24VDC) to Terminal (+) on the Power Input Terminal.
•
Wire the NEGATIVE (-24VDC) to Terminal (-) on the Power Input Terminal.