3-5
3.6 Normal
Power
On
When the
MINI CK100
is powered on after initial programming, the RUN MENU 1 is displayed
unless the hardware configuration has been changed.
3.6.1 Hardware Configuration
If the hardware configuration detected at power on differs from the one recorded in memory, the
following screen displays. This only happens if a circuit board has been added or removed
during power off, or a board has failed.
This screen disappears after 10 seconds if the question is not answered or if press a key.
If a board is removed or added must be necessary reply the instrument configuration.
3.7 Run
Menu
When the
Static Weight Indicator
is normally powered on after initial programming, the RUN
(RUN MENU 1) is displayed. The RUN menu can always be accessed by pressing the
RUN
key on the front panel.
3.7.1 Main Run Functions
Is composed of two screens. Press UP or DOWN keys for scroll.
3.7.1.1
Screen 1
The usual screen is the following:
The first line always displays the actual NET WEIGHT. A “Z” appears on the left side if the
“Auto zero tracking” option is enabled and the scale is unloaded. The load must stay low during
the cycle; otherwise, auto zero is aborted.
A “T” appears if tare weight has been acquired. The second (1) and third (2) lines are by
default blank, but can be programmed to show :
2.
The tare weight
3.
The actual gross weight
4.
The peak weight
5.
The reset total value
6.
The master total value
7.
Date and time
8.
A bar graph indicator
--CONFIG CHANGED
Acuire new
configuration
OK
ZT 0000.0 Ton
(1)
(2)
S/R TARE ALARM
Содержание Ramsey MINI CK100
Страница 1: ...1 Operating And Service Manual Ramsey MINI CK100 Weight Indicator MINI CK100 Part No...
Страница 4: ......
Страница 14: ......
Страница 24: ......
Страница 80: ......
Страница 86: ......
Страница 92: ......
Страница 94: ......
Страница 95: ...C 1 Appendix C Drawings Wiring Diagram CK 0000100 E001C...