95 Series Operators Guide
1-2
71-0011 — REV E
SPECIFICATIONS
** In range of ±2% O
2
from calibration point.
Specifications are subject to change without notice.
Table 1-1
95 Series Gas Monitor Specifications
Model Designation
(Gases Detected)
OX-95 (0-30.0% O
2
in 0.1% increments)
HS-95 (0-100 ppm H
2
S in 1 ppm increments)
CO-95 (0-500 ppm CO in 1 ppm increments)
Detection Method
Diffusion, electrochemical
Response Time
Accuracy
Repeatability
90% in 30 seconds
±5% of reading (±0.2% O
2
for OX-95**)
±3% of reading (±012% O
2
for OX-95**)
Gas Alarm Setpoints
OX-95: 19.5% vol, decreasing, (programmable)
23.5% vol, increasing, (programmable)
HS-95: 10 ppm, and 15 ppm, (programmable)
CO-95: 25 ppm, 200 ppm, (programmable)
Gas Alarm Delay
3 sec. (programmable to 0, 1, 2, or 3 sec.)
Other Alarm Modes
Weak or failed sensor, low or dead battery
Operator Controls
- Power
switch
- ZERO/-
button
- SPAN/+ button
Dimensions
Weight
4.5 in. H x 2.5 in.W x 1.0 in. D
6.5 ounces
Battery Life
(approximate)
Continuous, non-alarm operation per one 9V
alkaline battery:
OX-95: 3,200 hours
CO-95 and HS-95: 2,500 hours
Standard* and
Optional Accesso-
ries
Operator’s guide*, hand-aspirated sample-draw
adapter, earphone, test kits, vibrating alarm,
*strap.
Operating Tempera-
ture and Humidity
-4º F (-20º C) to 113º F (45º C)
0-95% relative humidity (RH), non-condensing
Regulatory
Approvals
UL classified; CSA classified
Class I, Division 1, Groups A, B, C, and D
DEMKO EEx ia IIB T2
Содержание CO-95