7
ENGLISH
GENERAL
GENERAL
Description
TSOL CN S BLU 30°
150/1
200/1
220/2
300/2
300/3
S
77
85
88
95
95
W
V
153
202
223
278
278
I
Qnonsol M (***)
1109
1132
1007
1044
1023
kWh/a
Qnonsol L (***)
2122
2124
1711
1723
1494
kWh/a
Qnonsol XL (***)
3610
3600
2977
2970
2527
kWh/a
Qnonsol XXL (***)
4753
4738
4022
4008
3457
kWh/a
(*) Tested according to EN 12975, referred to a 33,3% water-glycol mix, flow rate of 140 l/h , and irradiation G = 800 W/m
2
.
Tm = (Coll._inlet _temp.+Coll._outlet_temp.)/2
T*m =
(Tm-T_ambient)/G
(**) Calculated with a temperature difference of 40K between the solar collector and the surrounding air, and with total solar
radiation of 1000 W/m
2
referred to the exposed area.
(***)
Value calculated in terms of primary electrical energy and/or calorific content of fuel under average climatic conditions,
in load profiles M, L, XL and XXL, with permanent backup and storage cylinder inside building.
OVERALL DIMENSIONS AND WEIGHTS
L
P
H
30°
Description
TSOL CN S BLU 30°
150/1
200/1
220/2
300/2
300/3
Empty weight
112
136
162
198
236
kg
Full weight
274
352
401
496
597
kg
L
1310
1310
2400
2400
3500
mm
P
2310
2310
2310
2310
2310
mm
H
1130
1130
1130
1130
1130
mm
WATER CIRCUIT
UAC
Domestic hot water outlet
EAF
Domestic cold water inlet
1
Primary (solar collector) circuit safety valve (2.5 bar)
2
Non-return valve - safety valve of secondary (DHW)
circuit (10 bar)
3
Storage cylinder
4
Collector
5
DHW tank (secondary circuit)
6
Primary circuit
7
Magnesium anode
8
Primary circuit filling/drain cock
9
Insulation
CWI
HWO
1
8
2
3
5
7
6
6
4
9
heat exchange
heat exchange