background image

4

ENGLISH

GENERAL

GENERAL

GENERAL SAFETY INFORMATION

Check that the product is complete, undamaged 

and as ordered as soon as you receive it. Report any 

discrepancies or damage to the 

T

 dealer 

who sold it.

This product must be installed by a legally qualified 

heating engineer. On completion of the installation, 

the installer must issue the owner with a declaration 

of conformity confirming that the installation has been 

completed to the highest standards in compliance 

with the instructions provided by 

T

 in this 

instruction manual, and that it conforms to all applicable 

laws and standards.

This product must only be used for the purpose for which 

it is designed and made, as specified by 

T

T

 declines all responsibility, contractual 

or other, for damage to property or injury to persons or 

animals caused by improper installation, adjustment, 

maintenance or use.

Make sure that the roof is strong enough to support the 

weight of the solar water heating system under operating 

conditions. Also make sure that the section of roof chosen 

for the installation enjoys a high level of insolation, and 

is not shaded during the day by tall plants, trees, other 

houses, hills, etc..

The installation of a solar water heating system modifies 

the existing structure of the roof. Verify the suitability of all 

roof elements and if necessary adapt them to avoid leaks 

or damage by wind and/or snow loads.

If the system is installed in an area subject to gusting 

winds or snow loads in excess of the limits given in the 

technical specifications, consult your supplier for advice.

Snow can build up in the sheltered area behind the solar 

water heating system. Provide adequate protection to 

avoid increasing the static load on the roof.

The system must be serviced at least once a year.

The water supply circuit must permit the storage cylinder 

to be filled and emptied in safety. Shut-off valves must 

therefore be easily accessible to the user and the 

operation of emptying the storage cylinder must not 

create any risk of flooding or other damage.

Insulate the domestic water pipes (hot and cold) and 

the pipes of the solar collector circuit. Provide suitable 

insulation for all outdoor accessories.

The point through which the water pipes enter the 

building must be rain-proof and damp-proof.

If you notice any water or heat transfer liquid leaks, 

disconnect the system immediately from the mains 

electricity supply (if a supplementary heating element 

is installed), shut off the water supply, and notify 

T

’s Technical Assistance Service or a 

qualified heating engineer immediately.

Make sure that the water-glycol mix in the solar collector 

circuit is able to resist the minimum temperatures likely to 

occur in the place of installation.

The system can reach very high temperatures. Safety 

valves can therefore discharge extremely hot liquids. 

Make sure that the expansion vessel is of a suitable size 

and design for use in solar water heating systems.

Use proper slings to lift and move the elements of the 

system. Never lift the collector or storage cylinder by 

their fittings. Avoid subjecting the collector to impacts 

or mechanical strain, and take care to protect the glass 

panel. Use the personal protection equipment required 

by applicable safety standards.

PRECAUTIONS

Never attempt to install the system without using the 

personal protection equipment and without following the 

safety precautions specified by applicable occupational 

safety standards.

Never install solar collectors on roofs without an adequate 

lightning protection system.

Never install the system without providing proper 

drainage for the two safety valves: that of the domestic 

hot water circuit and that of the primary (solar collector) 

circuit.

If the storage cylinder is equipped with a supplementary 

heating element, never attempt any cleaning or 

maintenance without first disconnecting it from the mains 

power supply.

Do not allow children or infirm persons to operate the 

system unsupervised.

Do not tamper with or adjust the safety or control devices 

without prior authorisation and instructions from the 

manufacturer.

Never use anti-freeze other than that supplied by 

T

 to fill or top up the solar collector circuit. 

Mixing different products can reduce the anti-freeze 

protection provided.

Never drain the solar collector circuit under sunny 

conditions or when the collector is hot.

Do not dispose of packaging material into the 

environment, or leave it within the reach of children, since 

it can become a potential hazard. Dispose of packaging 

material in compliance with applicable legislation.

General

Содержание TSOL CN 150/1 S BLU 30

Страница 1: ...TSOL CN S BLU 30 system INSTALLER TECHNICAL ASSISTANCE CENTRE AND USER MANUAL...

Страница 2: ...t be required This instruction manual contains important instructions and precautions that must be observed to ensure the trouble free installation and efficient functioning of your T solar water heat...

Страница 3: ...4 General Safety Information 4 Precautions 4 Description of the system 5 Safety devices 5 Identification 5 System layout 6 Technical specifications 6 Overall dimensions and weights 7 Water circuit 7...

Страница 4: ...point through which the water pipes enter the building must be rain proof and damp proof b If you notice any water or heat transfer liquid leaks disconnect the system immediately from the mains electr...

Страница 5: ...T s Technical Assistance Service using original spare parts b Over temperature protection requires an adequate supply of cold water from the mains IDENTIFICATION T TSOL CN S BLU 30 systems are identi...

Страница 6: ...ion TSOL CN S BLU 30 150 1 200 1 220 2 300 2 300 3 Collector surface area 1 91 x 1 1 91 x 1 1 91 x 2 1 91 x 2 1 91 x 3 m2 x n of pan Exposed area 1 78 x 1 1 78 x 1 1 78 x 2 1 78 x 2 1 78 x 3 m2 x n of...

Страница 7: ...ted in terms of primary electrical energy and or calorific content of fuel under average climatic conditions in load profiles M L XL and XXL with permanent backup and storage cylinder inside building...

Страница 8: ...n only remove this film if you are going to put the system into service immediately b Take care not to lose the four flat seal rings 1 located in the corner profiles of each collector 1 Description TS...

Страница 9: ...olar collectors ideally facing south Avoid positions that are shaded by plants trees buildings or hills etc during the day Maintain the minimum distance A between the system and the edge of the roof R...

Страница 10: ...LER ASSEMBLY Start installing the system by assembling the mounting frame for flat roofs To do so follow the instructions given below 1 3 7 2 8 9 5 21 16 14 13 12 15 11 22 23 20 19 17 34 18 10 4 6 25...

Страница 11: ...6 8 11 11 15 13 Cross bracket 4 4 4 14 Plugs 8 8 12 12 16 15 M8 flanged nut 5 5 13 13 31 16 1 seal in corner profiles of collector 4 4 6 6 8 17 3 4 extension 1 1 1 1 1 18 3 4 straight union 2 2 2 2 2...

Страница 12: ...ing points b Check that the marks are square TSOL CN S BLU 30 150 1 200 1 220 2 300 2 300 3 A 300 300 300 300 300 mm B 1832 1832 1832 1832 1832 mm C 860 860 1160 1160 1160 mm D 825 1310 1310 1310 mm E...

Страница 13: ...13 ENGLISH INSTALLER INSTALLER Assemble the base by fixing the cross bars 3 to the storage cylinder supports 2 Fix the storage cylinder to its assembled base 3 3 2 11 10 2 15 10 12...

Страница 14: ...14 ENGLISH INSTALLER INSTALLER Turn the storage cylinder upright and fix the base to the roof Fix the collector support bars 1 to the storage cylinder and to the roof 1 1 1 10...

Страница 15: ...ER INSTALLER Steps valid for the following models 150 1 200 1 Loosely fit the bottom collector fixing brackets 5 Engage the collector in the bottom fixing brackets 5 and lay it on the collector suppor...

Страница 16: ...TALLER INSTALLER Tighten the bottom collector fixing brackets Secure the collector with fixing brackets 5 at the top 5 11 5 D2 D1 b Engage the ridges on the clamp D1 with the ridges on the frame of th...

Страница 17: ...ALLER Steps valid for the following models 220 2 300 2 Fix the bar props 9 to the cross bars 3 and the storage cylinder supports 2 Fit the cross brackets 13 to the bottom of the support bars 1 1 10 13...

Страница 18: ...18 ENGLISH INSTALLER INSTALLER Slide the brackets 4 over the bottom square tube 7 Secure the square tubes 7 to the cross brackets 13 4 7 7 15 10 13...

Страница 19: ...them on the square tubes 7 Fit the unions complete with seals to the collectors Secure the collectors at the sides with collector fixing brackets 5 5 11 5 11 D1 D2 4 7 7 A A A A B B B B B B A B b Enga...

Страница 20: ...LER Steps valid for the following models 300 3 Fix the additional cross bars 3 and the bar props 9 using the two screws already in place Fit the additional collector supports 8 to the cross bars 9 2 3...

Страница 21: ...21 ENGLISH INSTALLER INSTALLER Fit the cross brackets 13 to the support bars 1 and 8 1 10 13 15...

Страница 22: ...LISH INSTALLER INSTALLER Slide the brackets 4 over the bottom square tube 7 Join up and fix the square tubes 7 using the tube join 6 Secure the square tubes 7 to the cross brackets 13 7 15 10 13 4 7 7...

Страница 23: ...rackets 4 and lay them on the square tubes 7 Fit the unions complete with seals to the collectors Secure the collectors at the sides with collector fixing brackets 5 5 11 D1 D2 b Engage the ridges on...

Страница 24: ...bar safety valve 23 10 bar safety valve 22 straight flow and return unions 18 and straight extension union 17 23 22 18 18 17 Complete the collector water connections flow pipes return pipes drain cock...

Страница 25: ...with legislation governing the disposal of PVC SYSTEM WATER CONNECTIONS UAC Domestic hot water outlet 3 4 EAF Domestic cold water inlet 3 4 1 Primary solar collector circuit safety valve 2 5 bar 2 Non...

Страница 26: ...inder with cold water from the mains supply When water starts coming out of the hot water tap leave it run until you obtain an even flow then close the tap The DHW tank is now full FLUSHING THE SOLAR...

Страница 27: ...able above Pressure filling Use lengths of rubber hose to connect a pump between the container and the hose union on the filling drain cock 1 Open the cock Start up the pump and fill the solar heating...

Страница 28: ...ge dirt Visually inspect the storage cylinder Visually inspect the mounting frame and roof anchor points Inspect the insulation Make sure that the roof does not leak Make sure that the safety valves a...

Страница 29: ...ors are hot Cleaning inside the storage cylinder Proceed as follows to clean inside the storage cylinder Close the domestic cold water inlet cock Connect a hose to the storage cylinder drain cock D fi...

Страница 30: ...dition of the insulation around the pipes If the system is not going to be used for an extended period of time contact your local Technical Assistance Centre to have it made safe b The solar water hea...

Страница 31: ...because of over temperature during extended periods of disuse Top up the circuit with water glycol mix and bleed any air out Air bubbles have formed inside the circuit and are impeding natural circula...

Страница 32: ...egnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modif...

Отзывы: