TROUBLESHOOTING
FAULT
CAUSE
SOLUTION
No or insufficient domestic hot water
production
Unusually high draw of DHW.
- Check.
Water leaks in the DHW distribution
circuit.
- Check.
Collector glass covered in dust or
leaves.
- Clean.
The level of heat transfer liquid in the
circuit has dropped as the result of leaks
from the unions or because of over-
temperature during extended periods of
disuse.
- Top up the circuit with water/glycol mix
and bleed any air out.
Air bubbles have formed inside the
circuit and are impeding natural
circulation.
- Bleed the circuit by loosening the up-
permost union on the short pipe until
liquid comes out.
- Top up to replace any lost liquid.
Vibrations
Loose screws.
- Tighten the screws.