User Manual
3200 Series
44 Part No HA028651 Issue 11.0 July-12
9.1
Input/Output Parameters
9.1.1
Input/Output 1 List (IO-1)
May be configured as relay, logic or DC output or to accept a digital input from external switch contacts. Connections are
made to terminals 1A and 1B. OP1 beacon is operated from the IO-1 channel when it is configured as an output.
INPUT/OUTPUT LIST 1 ‘
I O -1
’
Name
Scrolling Display
Parameter Description
Value
Default
Access Level
1. i d
I/O 1 TYPE
I/O channel 1 hardware
type defined by the
hardware fitted
none
No input or output fitted
As
ordered
Read only
dC.OP
DC output - non-isolated
(see note 1)
ReLy
Relay output
L.IO
Logic Input/Output
SSR
Triac output
1.FUNC
I/O 1 FUNCTION
I/O channel function.
If the instrument is
ordered as valve
positioner (codes VC or
VP), only options available
are ,
none
,
d.out
,
UP
,
or
dwn
Note: If output 1 is set
to
Up
ensure the other
valve position output is
set to
dwn
and vice
versa
none
Disabled. If disabled no further
parameters are shown
HEAt
Conf
d.out
Digital output
UP
Valve open codes VC and VP only
dwn
Valve close codes VC and VP only
Heat
Heat output
CooL
Cool output
d.in
Digital input if ‘
1. i d
’ = ‘
L.IO
w.SP
Working setpoint re-transmission
Shown if I/O 1 TYPE =
dc.OP
Retransmission
PV
Process variable re-transmission
OP
Output power demand re-
transmission
1.SRC.A
I/O 1 SOURCE A
These parameters only
appear when the channel
function is a Digital
output,
i.e. 1.FUNC =
d.out
Selects an event status to
be connected to the
output channel.
The output status is the
result of an OR of Src A,
Src B, Src C, and Src D
Up to four events can,
therefore, operate the
output
See section 9.1.4
none
No event connected to the output
none
Conf
1.SRC.B
I/O 1 SOURCE B
AL1
Alarm 1
AL2
Alarm 2
1.SRC.C
I/O 1 SOURCE C
AL3
Alarm 3
AL4
Alarm4
1.SRC.D
I/O 1 SOURCE D
ALL.A
All alarms
nw.AL
Any new alarm
Ct.AL
CT alarm, load, leak & overcurrent
Lbr
Loop break alarm
Sbr
Sensor break alarm
t.End
Timer end status
t.run
Timer run status
mAn
Manual status
rmt.F
Remote fail - see section 9.1.2
Pwr.f
Power fail
prg.e
Programmer event. See also section
13.2.3
1. D . IN
DIGITAL INPUT
FUNCTION
This parameter is only
applicable to I/O 1 and
only appears if the
channel function is a
Digital IP
i.e. 1.FUNC =
d.in
Only one function may be
activated by a physical
input
none
Input not used
Ac.AL
Conf
Ac.AL
Alarm acknowledge
SP2
Setpoint 2 select
Loc.b
Front keypad disable (keylock)
t.res
Timer/programmer reset
t.run
Timer/programmer run
t.rrS
Timer/programmer run/reset. Make
to run, break to reset
t.HLd
Timer/programmer hold
Man
Manual status
Sby
Standby mode. In this mode control
outputs go to zero demand
rmt
Remote digital setpoint select
rec
Recipe select through IO1 digital input
UP
Remote key ‘Up’
dwn
Remote key ‘Down’
Содержание XST-2-0-12-1V1-E28
Страница 16: ...12 FURNACE TROUBLE SHOOTING ...
Страница 27: ...ɸ ...
Страница 28: ...ɸ ...
Страница 29: ......
Страница 30: ......
Страница 31: ...3216 3208 3204 User Manual 3200 Range Process Controller HA028651 11 Aug 2012 ...
Страница 170: ...User Manual 3200 Series 138 Part No HA028651 Issue 11 0 July 12 21 Certificate of Conformity ...
Страница 171: ......
Страница 173: ...Model 2416 Process Controller User Manual Part No HA025041_12 Date August 2014 ...
Страница 174: ...This page is intentionally blank ...
Страница 259: ...This page is intentionally blank ...