Configuration Installation and Operation Handbook
Name
Description
Values
Meaning
1A
Module 1 configuration
id
Identity of module installed
rELy
Relay output
dC.OP
Non-isolated DC output
LoG
Logic/PDSIO output
SSr
Triac output
For ‘
id
’ = ‘
rELy
’, ‘
LoG
’, or ‘
SSr
’ use this parameter table:
Func
Function
nonE
Function disabled
dIG
Digital output function
HEAt
Heating output
COOL
Cooling output
up
Open motorised valve
dwn
Close motorised valve
(
Only if
‘
id
’ = ‘
LoG
’)
SSr.1
PDSIO mode 1 heating
(
Only if
‘
id
’ = ‘
LoG
’)
SSr.2
PDSIO mode 2 heating
VAL.L
% PID demand signal giving minimum output
−
‘
Out.L
’
VAL.H
% PID demand signal giving maximum output
−
‘
Out.H
’
Out.L
Minimum average power
Out.H
Maximum average power
SEnS
Sense of output
(Only if
‘
Func
’ =
‘
dIG
’)
nor
Normal
(output energises when TRUE, e.g program events)
inv
Inverted
(output de-energises when TRUE, e.g. alarms)
When
‘
SEnS
’
appears, then further parameters are available. See the table on the next page.
VAL.L
Out.H
Out.L
VAL.H
PID Demand Signal
Electrical
Output
6-12 HA025041 issue 12 Aug 14
Содержание XST-2-0-12-1V1-E28
Страница 16: ...12 FURNACE TROUBLE SHOOTING ...
Страница 27: ...ɸ ...
Страница 28: ...ɸ ...
Страница 29: ......
Страница 30: ......
Страница 31: ...3216 3208 3204 User Manual 3200 Range Process Controller HA028651 11 Aug 2012 ...
Страница 170: ...User Manual 3200 Series 138 Part No HA028651 Issue 11 0 July 12 21 Certificate of Conformity ...
Страница 171: ......
Страница 173: ...Model 2416 Process Controller User Manual Part No HA025041_12 Date August 2014 ...
Страница 174: ...This page is intentionally blank ...
Страница 259: ...This page is intentionally blank ...