INSTALLATION
3-10
Manual No. 0-5164
ULTRA-CUT 400
3. The cutting machine frame is then connected to the “Star” point using 1/0 AWG (European 50 mm
2
) or larger
wire.
4. The plasma power supply work cable (see NOTE) is connected to the cutting table at the single point “Star”
ground.
NOTE
Do Not connect the work cable directly to the ground rod. Do not coil up excess ground or power
cables. Cut to proper length and reterminate as needed.
5. Make sure work cable and ground cables are properly connected. The work cable must have a solid con-
nection to the cutting table. The work and ground connections must be free from rust, dirt, grease, oil and
paint. If necessary grind or sand down to bare metal. Use lock washers to keep the connections tight. Using
electrical joint compound to prevent corrosion is also recommended.
6. The plasma power supply chassis is connected to the power distribution system ground as required by electri-
cal codes. If the plasma supply is close to the cutting table (see NOTE) a second ground rod is not usually
needed, in fact it could be detrimental as it can set up ground loop currents that cause interference.
When the plasma power supply is far away from the ground rod and interference is experienced, it may help
to install a second earth ground rod next to the plasma power supply. The plasma power supply chassis
would then be connected to this ground rod.
NOTE
It is recommended that the Plasma Power Supply be within 20 - 30 ft (6.1 – 9.1 m) of the cutting
table, if possible.
7. The plasma control cable should be shielded with the shield connected only at the cutting machine end.
Connecting the shield at both ends will allow ground loop currents which may cause more interference than
with no shield at all.
Creating An Earth Ground
1. To create a solid, low resistance, earth ground, drive a 1/2 in (12 mm) or greater diameter copper clad ground
rod at least 6 - 8 ft (1.8 - 2.4 m) into the earth so that the rod contacts moist soil over most of its length. De-
pending on location, a greater depth may be required to obtain a low resistance ground (see NOTE). Ground
rods, typically 10 ft (3.0 m) long, may be welded end to end for greater lengths. Locate the rod as close as
possible to the work table. Install a ground wire, 1/0 AWG (European 50 mm2) or greater, between the ground
rod and the star ground point on the cutting table.
NOTE
Ideally, a properly installed ground rod will have a resistance of three ohms or less.
To test for a proper earth ground, refer to the following diagram. Ideally, the reading on the multimeter should
be as shown.
Содержание Ultra-Cut 400
Страница 2: ...Blank...
Страница 4: ...Blank...
Страница 6: ...Blank...
Страница 10: ...This page intentionally blank...
Страница 11: ...Insert Table of Con tents tab here Discard this sheet...
Страница 12: ...This page intentionally blank...
Страница 16: ...TABLE OF CONTENTS This Page Intentionally Blank...
Страница 24: ...ULTRA CUT 400 GENERAL INFORMATION 1 8 Manual 0 5164 This Page Intentionally Blank...
Страница 25: ...ULTRA CUT 400 Manual 0 5164 1 9 GENERAL INFORMATION Insert Section 2 tab here Discard this sheet...
Страница 26: ...ULTRA CUT 400 GENERAL INFORMATION 1 10 Manual 0 5164...
Страница 36: ...SPECIFICATIONS 2 10 Manual No 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Страница 37: ...Manual No 0 5164 2 11 SPECIFICATIONS ULTRA CUT 400 Insert Sec 3 tab here discard this sheet...
Страница 38: ......
Страница 86: ...INSTALLATION 3 48 Manual No 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Страница 87: ...Manual No 0 5164 3 49 INSTALLATION ULTRA CUT 400 COPY CENTER Insert Sec 4 tab here discard this sheet...
Страница 88: ...Blank...
Страница 104: ...OPERATION 4 16 Manual No 0 5164 ULTRA CUT 400 This page intentionally blank...
Страница 105: ...Manual No 0 5164 4 17 OPERATION ULTRA CUT 400 COPY CENTER Insert Sec 5 tab here Discard this sheet...
Страница 106: ...This page intentionally blank...
Страница 110: ...MAINTENANCE 5 4 Manual 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Страница 111: ...Manual No 0 5164 5 5 MAINTENANCE ULTRA CUT 400 Insert Sec 6 tab here Discard this sheet...
Страница 112: ...MAINTENANCE 5 6 Manual 0 5164 ULTRA CUT 400 This page is blank intentionally...
Страница 139: ...Insert Sec 7 tab here Discard this sheet...
Страница 140: ...Blank...
Страница 147: ...Manual 0 5164 7 7 TORCH INFORMATION ULTRA CUT 400 Insert Section 8 and Section 8 tab here Discard this sheet...
Страница 148: ......
Страница 158: ...APPENDIX A 10 Manual 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Страница 163: ...Manual 0 5164 A 15 APPENDIX ULTRA CUT 400...
Страница 177: ...This Page Intentionally Blank...