Manual No. 0-5164
4-13 OPERATION
ULTRA-CUT 400
Fault Code Key
Error
Code
Error
Remedy / Comments
2-1
Missing AC Phase
Blown fuse, Broken or loose connection on power cable
2-2
Wrong input voltage
Inverter(s) not configured correctly for input voltage;
Poor power quality (brownouts, dropouts); Input power capacity / wiring
too small causing voltage drop; broken or loose power cable connec
-
tions.
2-3
Inverter or Pilot Regulator Over
Temperature
2-4
Power Supply not Ready
2-5
DC Output Low
Less than 60 VDC; Defective inverter, shorted output; CCM voltage sense
(J6) wire open or disconnected. Negative lead short to gnd. Shorted
chopper (100-300A only).
2-6
Inverter input fault
Capacitor bank voltage imbalance (400-460-600V only) or inverter
primary switching circuit overcurrent. If occasional may be line voltage
surge; remove power to reset. If persists defective inverter; LED on
inverter indicate which one.
2-7
Unexpected current
Current above 20A in work or pilot leads before pilot ignition; Possible
shorted torch; Defective current sensor.
2-8
Unexpected current in pilot circuit
Current above 5A in pilot circuit; wrong or mismatched consumables;
Pilot lead shorted to negative in torch tube; Possible shorted torch
2-9
Unexpected current in work lead
Current above 5A in work lead; Short to chassis in RAS; Negative lead
short to ground.
2-10
Reserved
No information available; Contact customer service
2-11
Reserved
No information available; Contact customer service
3-1
Gas Control Communication fault. Cannot establish Communication with gas control. If Gas Control is
GCM 200 or (rest of text unchanged.)
3-2
Gas Control reply fault.
Connection was established but (rest of text unchanged.)
3-3
Gas Supply Pressure out of range.
If Gas Control is GCM 200 or GCM 1000 Plasma may be less than 51
PSI; faulty or disconnected pressure SW. If GCM
2010 is rev AG or GCM2000 is rev AC (or later) or Gas Control has been
updated with 19X2219_AG (or later) PCB then Plasma or Shield supply
pressure may be outside the range of 105-135 PSI.
Unplugged or faulty pressure sensor; faulty gas control PCB.
3-4
Gas Control not ready
Purging; Not in RUN mode; Gas Control faulty, replace PCB
3-5
Gas Control Protocol Error
Verify Firmware revison for compatiblity with CCM
3-6
Reserved
No information available; Contact customer service
3-7
Gas Control sequencing error
Verify Firmware revison for compatiblity with CCM
3-8
Gas Control Type Mismatch
CCM must be Ultracut type for GCM 2010; Autocut type for GCM 2000,
GCM 1000 or GCM 200
3-9
Gas Control Command fault
Verify Firmware revison for compatiblity with CCM
3-10
Reserved
No information available; Contact customer service
3-11
Reserved
No information available; Contact customer service
3-12
Reserved
No information available; Contact customer service
3-13
Reserved
No information available; Contact customer service
Содержание Ultra-Cut 400
Страница 2: ...Blank...
Страница 4: ...Blank...
Страница 6: ...Blank...
Страница 10: ...This page intentionally blank...
Страница 11: ...Insert Table of Con tents tab here Discard this sheet...
Страница 12: ...This page intentionally blank...
Страница 16: ...TABLE OF CONTENTS This Page Intentionally Blank...
Страница 24: ...ULTRA CUT 400 GENERAL INFORMATION 1 8 Manual 0 5164 This Page Intentionally Blank...
Страница 25: ...ULTRA CUT 400 Manual 0 5164 1 9 GENERAL INFORMATION Insert Section 2 tab here Discard this sheet...
Страница 26: ...ULTRA CUT 400 GENERAL INFORMATION 1 10 Manual 0 5164...
Страница 36: ...SPECIFICATIONS 2 10 Manual No 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Страница 37: ...Manual No 0 5164 2 11 SPECIFICATIONS ULTRA CUT 400 Insert Sec 3 tab here discard this sheet...
Страница 38: ......
Страница 86: ...INSTALLATION 3 48 Manual No 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Страница 87: ...Manual No 0 5164 3 49 INSTALLATION ULTRA CUT 400 COPY CENTER Insert Sec 4 tab here discard this sheet...
Страница 88: ...Blank...
Страница 104: ...OPERATION 4 16 Manual No 0 5164 ULTRA CUT 400 This page intentionally blank...
Страница 105: ...Manual No 0 5164 4 17 OPERATION ULTRA CUT 400 COPY CENTER Insert Sec 5 tab here Discard this sheet...
Страница 106: ...This page intentionally blank...
Страница 110: ...MAINTENANCE 5 4 Manual 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Страница 111: ...Manual No 0 5164 5 5 MAINTENANCE ULTRA CUT 400 Insert Sec 6 tab here Discard this sheet...
Страница 112: ...MAINTENANCE 5 6 Manual 0 5164 ULTRA CUT 400 This page is blank intentionally...
Страница 139: ...Insert Sec 7 tab here Discard this sheet...
Страница 140: ...Blank...
Страница 147: ...Manual 0 5164 7 7 TORCH INFORMATION ULTRA CUT 400 Insert Section 8 and Section 8 tab here Discard this sheet...
Страница 148: ......
Страница 158: ...APPENDIX A 10 Manual 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Страница 163: ...Manual 0 5164 A 15 APPENDIX ULTRA CUT 400...
Страница 177: ...This Page Intentionally Blank...