AUTO-CUT 300 XT
Manual 0-5300
OPERATION
4-9
Code
Message
Remedy / Comments
244
Not used
Reserved for other model with another inverter section
245
Inverter 3A Input
Voltage Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter
Module 3 Section A; Poor AC Power Quality; Defective W2 contactor; Loose or open connec-
tion between input terminals and W2 contactor or contactor and input of Inverter Section;
Defective Inverter module
246
Inverter 3B Input
Voltage Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter
Module 3 Section B; Poor AC Power Quality; Defective W2 contactor; Loose or open connec-
tion between input terminals and W2 contactor or contactor and input of Inverter Section;
Defective Inverter module
247
Inverter 1A Circuit
Fault
Inverter Module 1 Section A detected a circuit fault; Damaged Inverter Module 1
248
Inverter 1B Circuit
Fault
Inverter Module 1 Section B detected a circuit fault; Damaged Inverter Module 1
249
Inverter 2A Circuit
Fault
Inverter Module 2 Section A detected a circuit fault; Damaged Inverter Module 2
250
Not used
Reserved for other model with another inverter section
251
Inverter 3A Circuit
Fault
Inverter Module 3 Section A detected a circuit fault; Damaged Inverter Module 3
252
Inverter 3B Circuit
Fault
Inverter Module 3 Section B detected a circuit fault; Damaged Inverter Module 3
253
Inverter 1A Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
254
Inverter 1B Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
255
Inverter 2A Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
256
Not used
Reserved for other model with another inverter section
257
Inverter 3A Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
258
Inverter 3B Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
259
Inverter 1A No Input
Power
Inverter section may have no input power. Contactor not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
260
Inverter 1B No Input
Power
Inverter section may have no input power. Contactor not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
261 Inverter 2A Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
262 Inverter 2B Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
263 Inverter 3A Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
264 Inverter 3B Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
265
Inverter 1A No Input
Power
Inverter section may have no input power. Contactor W1 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
266
Inverter 1B No Input
Power
Inverter section may have no input power. Contactor W1 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
Содержание AUTO-CUT 300 XT
Страница 6: ...This Page Intentionally Blank...
Страница 13: ...AUTO CUT 300 XT Manual 0 5300 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 52: ...This Page Intentionally Blank...
Страница 96: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 2 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 98: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 3 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 100: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 4 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 102: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 5 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 104: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 6 Display PCB Layout Test Point Test Point Art A 11679...
Страница 105: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 19 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 106: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 7 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 108: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 8 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 110: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 9 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 112: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 10 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 114: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 11 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 115: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 29 APPENDIX 12 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 116: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 13 Suppressor PCB Layout Art A 11684_AB...
Страница 161: ......