AUTO-CUT 300 XT
Manual 0-5300
SPECIFICATIONS
2-5
2.08 Gas Requirements
The customer will provide all gases and pressure regulators. Gases must be of high quality. Pressure regulators
shall be equipped with stainless-steel diaphragms and installed as close as possible to the Gas Console.
Auto-Cut 300
XT™
Power Supply: Gas Pressures, Flows, and Quality Requirements
Gas
Quality
Minimum Pressure
Flow
O
2
(Oxygen)
99.5% Purity
(Liquid recommended)
120 psi
8.3 bar / 827 kPa
200 scfh (95 lpm)
N
2
(Nitrogen)
99.5% Purity
(Liquid recommended)
<1000 ppm O
2
, <32 ppm
H
2
O)
120 psi
8.3 bar / 827 kPa
300 scfh (141.6 lpm)
Compressed
or Bottled Air
Clean, Dry,
Free of Oil (see Note 1)
120 psi
8.3 bar / 827 kPa
450 scfh (212.4 lpm)
H35 (Argon-Hydrogen)
H35 = 35% Hydrogen,
65% Argon
99.995% Purity
(gas
recommended)
120 psi
8.3 bar / 827 kPa
200 scfh (94.4 lpm)
H
2
O (Water)
See Note 2
55 psi (3.8 bar)
10 gph (0.6 lpm)
Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease
contamination from compressed or bottled air can cause fires in conjunction with oxygen.
For filtering, a coalescing filter able to filter to 0.01 microns should be placed as close as
possible to the gas inlets on the Gas Control Module.
Note 2: The tap water source does not need to be deionized, but in water systems with extremely high mineral content
a water softener is recommended. Tap water with high levels of particulate matter must be filtered.
Note 3: Water Pressure Regulator No. 8-6118 is recommended to ensure proper water pressure.
2.09 Gas Applications
MATERIAL
MILD STEEL
STAINLESS STEEL
ALUMINUM
OPERATION PLASMA SHIELD PLASMA
SHIELD
PLASMA
SHIELD
55A Cut
Air
Air
Air
Air
Air
Air
O
2
Air
100A Cut
Air
Air
Air
Air
Air
Air
N
2
H
2
0
N
2
H
2
0
O
2
Air
H35
N2
H35
N
2
200A Cut
Air
Air
Air
Air
Air
Air
N
2
H
2
0
N
2
H
2
0
O
2
Air
H35
N
2
H35
N
2
300A Cut
Air
Air
Air
Air
Air
Air
Содержание AUTO-CUT 300 XT
Страница 6: ...This Page Intentionally Blank...
Страница 13: ...AUTO CUT 300 XT Manual 0 5300 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 52: ...This Page Intentionally Blank...
Страница 96: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 2 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 98: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 3 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 100: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 4 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 102: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 5 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 104: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 6 Display PCB Layout Test Point Test Point Art A 11679...
Страница 105: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 19 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 106: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 7 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 108: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 8 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 110: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 9 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 112: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 10 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 114: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 11 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 115: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 29 APPENDIX 12 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 116: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 13 Suppressor PCB Layout Art A 11684_AB...
Страница 161: ......