AUTO-CUT 300 XT
Manual 0-5300
INSTALLATION
3-7
3.08 Ground Connections
A. Electromagnetic Interference (EMI)
Pilot arc starting generates a certain amount of electromagnetic interference (EMI), commonly called RF noise. This
RF noise may interfere with other electronic equipment such as CNC controllers, remote controls, height controllers,
etc. To minimize RF interference, follow these grounding procedures when installing automation (mechanized)
systems:
B. Grounding
1. The preferred grounding arrangement is a single point or “Star” ground. The single point, usually on the cutting
table, is connected with 1/0 AWG (European 50 mm
2
) or larger wire to a good earth ground (measuring leass
than 3 ohms; an ideal ground measures 1 ohm or less. Refer to paragraph ‘C’, Creating An Earth Ground. The
ground rod must be placed as close as possible to the cutting table, ideally less than 10 ft (3.0 m), but no more
than 20 ft (6.1 m) from the cutting table.
NOTE!
All ground wires should be as short as possible. Long wires will have increased
resistance to RF frequencies. Smaller diameter wire has increased resistance to
RF frequencies, so using a larger diameter wire is better.
2. Grounding for components mounted on the cutting table (CNC controllers, height controllers, plasma remote
controls, etc.) should follow the manufacturer’s recommendations for wire size, type, and connection point
locations.
For Victor Thermal Dynamics components it is recommended to use a minimum of 10 AWG (European 6 mm
2
)
wire or flat copper braid with cross section equal to or greater than 10 AWG connected to the cutting table frame.
The connection point must be to clean bare metal; rust and paint make poor connections. For all components,
wires larger than the recommended minimum can be used and may improve noise protection.
3. The cutting machine frame is then connected to the “Star” point using 1/0 AWG (European 50 mm
2
) or larger
wire.
4. The plasma power supply work cable (see NOTE) is connected to the cutting table at the single point “Star”
ground.
NOTE!
Do Not connect the work cable directly to the ground rod.
5. Make sure work cable and ground cables are properly connected. The work cable must have a solid connection
to the cutting table. The work and ground connections must be free from rust, dirt, grease, oil and paint. If
necessary grind or sand down to bare metal. Use lock washers to keep the connections tight. Using electrical
joint compound to prevent corrosion is also recommended.
6. The plasma power supply chassis is connected to the power distribution system ground as required by electrical
codes. If the plasma supply is close to the cutting table (see NOTE) a second ground rod is not usually needed,
in fact it could be detrimental as it can set up ground loop currents that cause interference.
When the plasma power supply is far away from the ground rod and interference is experienced, it may help
to install a second earth ground rod next to the plasma power supply. The plasma power supply chassis would
then be connected to this ground rod.
NOTE!
It is recommended that the Plasma Power Supply be within 20 -
30 ft (6.1 – 9.1 m) of the cutting table, if possible.
7. The plasma control cable should be shielded with the shield connected only at the cutting machine end. Con
-
necting the shield at both ends will allow ground loop currents which may cause more interference than with
no shield at all.
Содержание AUTO-CUT 300 XT
Страница 6: ...This Page Intentionally Blank...
Страница 13: ...AUTO CUT 300 XT Manual 0 5300 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 52: ...This Page Intentionally Blank...
Страница 96: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 2 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 98: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 3 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 100: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 4 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 102: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 5 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 104: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 6 Display PCB Layout Test Point Test Point Art A 11679...
Страница 105: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 19 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 106: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 7 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 108: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 8 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 110: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 9 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 112: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 10 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 114: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 11 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 115: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 29 APPENDIX 12 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 116: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 13 Suppressor PCB Layout Art A 11684_AB...
Страница 161: ......