AUTO-CUT 300 XT
Manual 0-5300
APPENDIX
A-43
Arc starter without Spark Gap (Ultra-Cut)
1. Check for power to the RAS 1000XT’s Ignition Module during the 15 seconds following preflow (ignition
phase). Arc starter power comes through the rear panel circuit breaker CB4, make sure it isn’t tripped.
a. During the ignition phase, measure for 120 VAC at the input terminals marked 120 VAC on the Ignition
module, a gray rectangular box with screw terminals on one side.
WARNING
Do not let the meter probes (or your hands) come in contact with the other terminals
marked Hb and Ho or the other end of the wires connected to them. These can have
10,000 volt pulses which can cause physical harm and will damage your meter.
2. If 120 VAC is not present go to step 3.
a. If 120 VAC is present and still no spark, the Ignition Module may be bad.
3. 120 VAC to the remote Arc Starter comes from J59-7 & 9 on the power supply rear panel and connects to
J58-7 & 9 on the RAS1000XT. Remove the cable from J59 and during the ignition phase measure for 120 VAC
between pins 7 & 9.
a. If 120 VAC is present problem is in the cable to the RAS 1000 XT or the J58 connector and internal harness
in the Arc Starter.
b. If 120 VAC is present proceed to the next step.
4. 120 VAC to J59 comes from the relay board J8-3 with return on pin 11. On the Relay board, RF ON LED,
D23, should be on during the igniting phase. If it is not skip to the next step.
a. If D23 is on and there is not 120 VAC at J8-3 & 11 then the Relay board is bad.
Either Arc Starter
5. /RAS ON signal not on. CCM sends active low signal “ /RAS ON” over the 40 pin ribbon cable on pin
16 to the Relay & Interface board. On the relay board RAS Control relay (K2) closes (RF ON LED, D23 on)
sending 120 VAC to J8-3 with return on J8-11. From here it either goes to the HF transformer T2 (AC200XT)
or to J59 as described above.
a. Measure the signal “/RAS ON” on pin 16 of the 40 pin ribbon cable relative to TP1 on either the CCM
I/O board or the Relay board. If it is low (less than 1V) skip to step 6. Otherwise continue this step.
NOTE!
If the CCM thinks there is already a pilot it would not enable the HF. Pilot board has
a current sensor that sends a differential analog pilot current level signal to the Relay
board which in turn passes that signal to the CCM. On the Relay board D11 LED “Pilot
Current Detected” or just “PILOT” lights if it sees a signal from the pilot board.
Содержание AUTO-CUT 300 XT
Страница 6: ...This Page Intentionally Blank...
Страница 13: ...AUTO CUT 300 XT Manual 0 5300 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 52: ...This Page Intentionally Blank...
Страница 96: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 2 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 98: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 3 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 100: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 4 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 102: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 5 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 104: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 6 Display PCB Layout Test Point Test Point Art A 11679...
Страница 105: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 19 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 106: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 7 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 108: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 8 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 110: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 9 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 112: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 10 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 114: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 11 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 115: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 29 APPENDIX 12 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 116: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 13 Suppressor PCB Layout Art A 11684_AB...
Страница 161: ......