PRO-WAVE 300TSW
August 10, 2005
7-1
SECTION 7:
ADVANCED TROUBLESHOOTING
If the problem cannot be solved by the basic (external)
trouble shooting guide, the Power Source enclosure will
have to be removed. The advanced level of
troubleshooting allows the technician with a few common
tools to remove the plastic enclosure and analyse some
failures.
Refer to section 7.01 for the necessary equipment and
tools.
WARNING
Never open the Power Source enclosure
unless the mains supply voltage to the Power
Source is disconnected from the power point.
CAUTION
When removing the locking type connectors
and board supporters, disengage the locking
mechanism first and then disconnect them.
7.01 Test Equipment and Tools
a. Digital Multi-meter with diode test function and
insulated shaft test probes.
b. Phillips, and slotted head screwdriver.
c. Long nose pliers, diagonal cutter and circlip pliers.
d. Nut driver and Open end spanner, 5.5mm, 7mm,
8mm, 10mm, 12mm, 17mm.
7.02 Removing the Enclosure
1. Confirm that the switch of power supply and the
switch on switchboard (distribution panel) are all OFF.
WARNING
The capacitors inside the power supply will
slowly discharged after you turn off the switch
of the power source or the switch at power
point (distribution panel). Wait at least 5
minutes for the discharge to complete.
2. Remove all screws and nuts on the side covers.
Art # A-05570
Figure 7-1: Removing side covers
3) Loosen the screws on the front panel and the rear
panel by turning them approximately two turns CCW.
NOTE
DO NOT remove the screws completely.
Art # A-05571
Figure 7-2: Removing front and rear panels