PRO-WAVE 300TSW
4-16
August 10, 2005
4.09 Welding Parameter Setting (Factory
Setting)
CAUTION
When replacing PCB5 (WK-4919) the Welding
Parameter Factory Setting must be set.
STD
SL OPE
SPOT
UP
SL OPE
PUL SE
FR EQ.
PE AK
CUR .
Hz
%
(m)sec
A
R EPE AT
(WE L D)
HOT
START
DOWN
SL OPE
PR E-FL OW
B ASE
PUL SE
WIDTH
CRATE R
CUR .
INITIAL
CUR .
LIFT TIG
HF TIG
STICK
PUL SE
ON
WAV E
B AL A NCE
A C
DC
AC /DC
POST-FL OW
PUL SE
SPOT
TIME
A C
FR EQ.
SAV E
L OAD
ON
OFF
V R D
R efer to Manual
for correct use
Figure 4-13: Front panel
1. Turn on the power source
2. After more than 8 sec, set weld mode to (DC) STICK
mode If from the beginning, the display was in (DC)
STICK mode, then push HF TIG and LIFT TIG button
until it rotates back (1cycle) to the (DC) STICK mode
display.
3. Set BASE current to 27A.
4. Push encoder button again until the LED welding
parameter rotates to the BASE current setting.
5. Set BASE current to 46A.
6. To record the time changes press and hold the encoder
button for more than 5 seconds or until the buzzer
sounds three beeps.
7. Turn off the power source