PRO-WAVE 300TSW
6-12
August 10, 2005
Description Possible
Cause
Remedy Remarks
E82 error code displayed
Link switch plug not
connected.
A. Link switch plug
not connected.
A. Check link switch plug
connection at connector
CN4 on PCB3 (WK-4819).
No weld current is
available. Buzzer
sounds constantly.
Switch machine off.
B. Accumulation of
dust.
B. Refer to visual inspection
section.
C. Faulty PCB3 (WK-
4819)
C. If error code E82 still
appears after checking
the above then replace
PCB3 (WK-4819).
E83 error code displayed
CPU checks mains supply
(input) voltage when the
on/off switch on rear panel
of machine is turned ON.
A. The Primary
supply (input)
voltage
fluctuates and is
not stable.
A. Check input power supply
cable electrical
connections.
No weld current is
available. Buzzer
sounds constantly.
Switch machine off
then on to reset E83
error.
B. Connector plug
connections
from PCB2 (WK-
4983) to PCB9
(WK-4917).
B. Check wiring and
connections at connector
CN1 on PCB9 (WK-4917)
and connector CN1 on
PCB2 (WK-4983) are
connected firmly.
C. PCB plug
connections
from PCB2 (WK-
4983) to PCB3
(WK-4819).
C. Check connections from
PCB2 (WK-4983) to PCB3
(WK-4819) are connected
firmly.
D. Defective PCB3
(WK-4819)
D. If error code E83 still
appears after checking
the above then replace
PCB3 (WK-4819).