FABRICATOR 140, 180
ADVANCED TROUBLESHOOTING
Manual 0-4992
6-6
Janua
r
y 25, 2008
6.12 T1 Transformer Test Procedure
Disconnect and isolate the t
r
ansfo
r
me
r
seconda
r
y wi
r
e f
r
om the Rectifie
r
Assembly Te
r
minal AC1. Refe
r
to
Figu
r
e 6-1. Connect the mete
r
between the wi
r
e that was
r
emoved f
r
om te
r
minal AC1 to te
r
minal AC2. Close the
MIG gun switch and obse
r
ve the voltage. Repeat this test fo
r
each position of the Voltage Cont
r
ol Switch.
Fabricator 140
Voltage Cont
r
ol Switch (SW1) position #
T1 Seconda
r
y Voltage
1 15
2 18
3 21
4 25
Fabricator 180
Voltage Cont
r
ol Switch (SW1) position #
T1 Seconda
r
y Voltage
1 17
2 19
3 21
4 23
5
26
6 31
6.13 C1 & C2 Test Procedure
Use a Capacito
r
Teste
r
if available, othe
r
wise visually check C1 & C2 fo
r
damage and make su
r
e the
r
elief valve is not
blown. Disconnect one of the wi
r
es connecting C1 & C2 to the
r
ectifie
r
assembly. Check continuity between the two
buss ba
r
s on C1 & C2. The mete
r
should show a cha
r
ging action. Reve
r
se the pola
r
ity of the p
r
obes and you should
see the
r
eading dec
r
ease to ze
r
o and then sta
r
t a cha
r
ging action again.
Replace the capacito
r
s if a sho
r
t o
r
open is found. Reconnect wi
r
es that we
r
e p
r
eviously
r
emoved.
Содержание Fabricator 140
Страница 2: ......
Страница 24: ...FABRICATOR 140 180 INTRODUCTION Manual 0 4992 2 8 January 25 2008...
Страница 36: ...FABRICATOR 140 180 INSTALLATION Manual 0 4992 3 12 January 25 2008...
Страница 56: ...FABRICATOR 140 180 BASIC TROUBLESHOOTING Manual 0 4992 5 6 January 25 2008...
Страница 67: ...PARTS LISTS FABRICATOR 140 180 January 25 2008 7 5 Manual 0 4992 1 2 3 4 5 6 7 8 9 10 11 12 Art A 08258...
Страница 69: ...PARTS LISTS FABRICATOR 140 180 January 25 2008 7 7 Manual 0 4992 1 2 3 4 5 6 7 8 9 11 12 10 13 Art A 08259...
Страница 79: ......
Страница 82: ......