FABRICATOR 140, 180
INSTALLATION
Manual 0-4992
3-6
Janua
r
y 25, 2008
3.08 Polarity Changeover
!
WARNING
ELECTRIC SHOCK CAN KILL! Make ce
r
tain the machine is unplugged f
r
om the powe
r
r
eceptacle. Do not
plug machine in until told to do so in these inst
r
uctions
As delive
r
ed f
r
om the facto
r
y, the output pola
r
ity is connected as DCEP (
r
eve
r
se pola
r
ity). The output te
r
minals a
r
e
located on the inte
r
io
r
panel of the welding powe
r
sou
r
ce.
CABLE TO GUN
CABLE TO WORK
1. GMAW* – Solid Wi
r
e &
flux co
r
ed with shielding gas
1. DCEP – Reve
r
se Pola
r
ity* 1. Connected to (+)
Pos. output te
r
minal
1. Connected to (-)
Neg. output te
r
minal
2. FCAW* – Self-shielding
Wi
r
e – no Shielding Gas
2. DCEN – St
r
aight Pola
r
ity* 2. Connected to (-)
Neg. output te
r
minal
2. Connected to (+)
Pos. output te
r
minal
* Exception: Contact your filler metal supplier for recommended polarity.
CABLE CONNECTIONS
PROCESS
POLARITY
Table 3-1: P
r
ocess Cable Connections
Connection for GMAW (reverse polarity DCEP)
1. Open the doo
r
to the machine.
2. Remove the pola
r
ity te
r
minal knobs.
3. Set up the pola
r
ity (as pe
r
Table 3-1 above) by
r
emoving the leads f
r
om the te
r
minals and
r
eve
r
sing them if necessa
r
y. Refe
r
to Figu
r
e 3-4.
4. Replace the pola
r
ity te
r
minal knobs.
NOTE
Ensu
r
e that the pola
r
ity te
r
minal knobs a
r
e
tightly secu
r
ed and that the
r
e is no connection
between positive and negative te
r
minals.
Connection for FCAW (straight polarity DCEN)
1. Open the doo
r
to the machine.
2. Remove the pola
r
ity te
r
minal knobs.
3. Set up the pola
r
ity (as pe
r
Table 3-1 above) by
r
emoving the leads f
r
om the te
r
minals and
r
eve
r
sing them if necessa
r
y. Refe
r
to Figu
r
e 3-5.
4. Replace the pola
r
ity te
r
minal knobs.
NOTE
Ensu
r
e that pola
r
ity te
r
minal knobs a
r
e tightly
secu
r
ed and that the
r
e is no connection
between positive and negative te
r
minals.
Polarity
Termi
n
al
Lead
s
Polarity
Termi
n
al
K
n
ob
s
Ga
s
Ho
s
e
Normally
Co
nn
ected
Art # A-08336
Figu
r
e 3-4: Connection fo
r
GMAW (
r
eve
r
se pola
r
ity DCEP)
Polarity
Termi
n
al
Lead
s
Polarity
Termi
n
al
K
n
ob
s
Ga
s
Ho
s
e
Normally
Di
s
co
nn
ected
Art # A-08337
Figu
r
e 3-5: Connection fo
r
FCAW (st
r
aight pola
r
ity DCEN)
Содержание Fabricator 140
Страница 2: ......
Страница 24: ...FABRICATOR 140 180 INTRODUCTION Manual 0 4992 2 8 January 25 2008...
Страница 36: ...FABRICATOR 140 180 INSTALLATION Manual 0 4992 3 12 January 25 2008...
Страница 56: ...FABRICATOR 140 180 BASIC TROUBLESHOOTING Manual 0 4992 5 6 January 25 2008...
Страница 67: ...PARTS LISTS FABRICATOR 140 180 January 25 2008 7 5 Manual 0 4992 1 2 3 4 5 6 7 8 9 10 11 12 Art A 08258...
Страница 69: ...PARTS LISTS FABRICATOR 140 180 January 25 2008 7 7 Manual 0 4992 1 2 3 4 5 6 7 8 9 11 12 10 13 Art A 08259...
Страница 79: ......
Страница 82: ......