
INSTALLATION
FABRICATOR 140, 180
Janua
r
y 25, 2008
3-1
Manual 0-4992
SECTION 3:
INSTALLATION
3.01 Location
Fo
r
best ope
r
ating cha
r
acte
r
istics and longest unit life,
take ca
r
e in selecting the installation site. Avoid locations
exposed to high humidity, dust, high ambient tempe
r
atu
r
e,
o
r
co
rr
osive fumes. Moistu
r
e can condense on elect
r
ical
components, causing co
rr
osion o
r
sho
r
ting of ci
r
cuits.
Di
r
t on components will
r
etain this moistu
r
e and also
inc
r
eases wea
r
on moving pa
r
ts.
Adequate ai
r
ci
r
culation is needed at all times in o
r
de
r
to
assu
r
e p
r
ope
r
ope
r
ation. P
r
ovide a minimum of 12”
(300mm) of f
r
ee ai
r
space at both the f
r
ont and
r
ea
r
of
the unit. Make su
r
e that the ventilation openings a
r
e not
obst
r
ucted.
CAUTION
The Fab
r
icato
r
is not suitable fo
r
use in
r
ain.
3.02 Safety
Refe
r
to additional installation inst
r
uctions unde
r
the
SAFETY INSTRUCTIONS AND WARNINGS (Section 1) in
this manual.
3.03 Grounding
The inte
r
nal f
r
ame of this welding machine should be
g
r
ounded fo
r
pe
r
sonal safety. Whe
r
e g
r
ounding is
mandato
r
y unde
r
state o
r
local codes, it is the
r
esponsibility of the use
r
to comply with all applicable
r
ules and
r
egulations. Whe
r
e no state o
r
local codes exist,
it is
r
ecommended that the National Elect
r
ical Code be
followed.
3.04 Electrical Input Requirements
Plug the input co
r
d into a p
r
ope
r
ly g
r
ounded and p
r
otected
(by fuse o
r
ci
r
cuit b
r
eake
r
) mains
r
eceptacle capable of
handling a minimum of 20 Ampe
r
es. The Fab
r
icato
r
140
r
equi
r
es a 120VAC supply voltage and the Fab
r
icato
r
180
r
equi
r
es a 230VAC supply voltage.
The Fab
r
icato
r
140’s powe
r
co
r
d is equipped with a NEMA
5-15P plug and will only connect to a NEMA 5-15P
r
eceptacle.
The Fab
r
icato
r
180’s powe
r
co
r
d is equipped with a NEMA
6-50P plug and will only connect to a NEMA 6-50P
r
eceptacle.
CAUTION
Consult the nameplate fo
r
p
r
ope
r
input voltage
and input ampe
r
age. The method of
installation, conducto
r
size, and ove
r
-cu
rr
ent
p
r
otection shall confo
r
m to the
r
equi
r
ements
of the local elect
r
ical code. All installation
wi
r
ing and machine connection shall be done
by a competent elect
r
ician.
The National Elect
r
ical Code (A
r
ticle 630B) p
r
ovides
standa
r
ds fo
r
ampe
r
age handling capability of supply
conducto
r
s based on the duty cycle of the welding powe
r
sou
r
ce. The Fab
r
icato
r
140 has a 20% duty cycle (2
minutes of eve
r
y 10 minutes can be used fo
r
welding)
and the Fab
r
icato
r
180 has a 25% duty cycle. The powe
r
co
r
ds supplied with these units comply with these
standa
r
ds. Ensu
r
e that the building supply and
r
eceptacle
comply with NEC standa
r
ds and any additional state and
local codes.
NOTE
The supply wi
r
ing fo
r
the welding powe
r
sou
r
ce must be capable of handling a
minimum of 20 ampe
r
es. The welding powe
r
sou
r
ce must be the only load connected to
the supply ci
r
cuit. Poo
r
unit pe
r
fo
r
mance o
r
f
r
equently opening line fuses o
r
ci
r
cuit
b
r
eake
r
s can
r
esult f
r
om an inadequate o
r
imp
r
ope
r
supply.
CAUTION
Do not connect the Fab
r
icato
r
140 to an input
powe
r
supply with a
r
ated voltage that is
g
r
eate
r
than 132 +10% VAC. Do not
r
emove
the powe
r
co
r
d g
r
ound p
r
ong.
CAUTION
Do not connect the Fab
r
icato
r
180 to an input
powe
r
supply with a
r
ated voltage that is
g
r
eate
r
than 255 + 10% VAC. Do not
r
emove
the powe
r
co
r
d g
r
ound p
r
ong.
Содержание Fabricator 140
Страница 2: ......
Страница 24: ...FABRICATOR 140 180 INTRODUCTION Manual 0 4992 2 8 January 25 2008...
Страница 36: ...FABRICATOR 140 180 INSTALLATION Manual 0 4992 3 12 January 25 2008...
Страница 56: ...FABRICATOR 140 180 BASIC TROUBLESHOOTING Manual 0 4992 5 6 January 25 2008...
Страница 67: ...PARTS LISTS FABRICATOR 140 180 January 25 2008 7 5 Manual 0 4992 1 2 3 4 5 6 7 8 9 10 11 12 Art A 08258...
Страница 69: ...PARTS LISTS FABRICATOR 140 180 January 25 2008 7 7 Manual 0 4992 1 2 3 4 5 6 7 8 9 11 12 10 13 Art A 08259...
Страница 79: ......
Страница 82: ......