2-12
Themis Computer
NanoPAK
®
User Manual
Version 1.0
2.3.2.2 COM B
COM B only runs in RS232 mode, with no control signals, only TXD and RXD. The
maximum baud rate is 115200 baud.
2.3.3
General Purpose I/O
There are 4 General Purpose Inputs and 4 General Purpose Outputs, (GPIO), avail-
able at the 69-pin connector J1. (On systems with SATA capability, 2 of each of
these ports, GPI2/GPO2 and GPI3/GPIO3, share pins on J1 with the RS232 modem
control signals in order to make connections available for the SATA pairs.) These
signals are at 3.3V logic level, routed to and from the COMExpress
®
connector on
the carrier board through buffers. Refer to
Table A-1
on page A-2 of Appendix A for
Figure 2-9.
RS485 Half-Duplex Bus Configuration
Содержание NanoPAK
Страница 5: ...iii Themis Computer NanoPAK User Manual VersionRevisionHistory Version 1 0 December 2012...
Страница 8: ...vi Themis Computer NanoPAK User Manual Version 1 0...
Страница 18: ...xvi Themis Computer NanoPAK User Manual Version 1 0...
Страница 52: ...2 20 Themis Computer NanoPAK User Manual Version 1 0...
Страница 92: ...4 10 Themis Computer NanoPAK User Manual Version 1 0 4 3 4 ACPI Settings Figure 4 6 ACPI Settings...
Страница 105: ...4 23 Themis Computer 4 AMI BIOS Setup Utility 4 5 Boot Settings Figure 4 18 Boot Settings...
Страница 109: ...4 27 Themis Computer 4 AMI BIOS Setup Utility 4 7 Advanced Chipset Settings Figure 4 21 Advanced Chipset Settings...
Страница 116: ...4 34 Themis Computer NanoPAK User Manual Version 1 0...
Страница 149: ...C 3 Themis Computer C Repackaging Instructions Figure C 1 Figure C 1 Order of Assembly...
Страница 150: ...C 4 Themis Computer NanoPAK User Manual Version 1 0...