Chapter 1: ProtectServer PCIe 2 Hardware Installation
Testing the battery
You can use the utilities provided with the adapter to query the state of the battery. In ProtectToolkit-C, use
ctcheck -b batterystatus
to return a state of
Good
/
Low
. For more information about querying the state of
the battery of the HSM, see the reference guide for your ProtectToolkit software.
The real-time clock (RTC) and memory retain their data as long as the adapter is in a powered system. The
RTC performs a daily battery check. If it detects a low-battery warning, the battery may need to be replaced. If
the adapter has been de-powered or removed from its system, the data in its memory is suspect. If the adapter
has been continuously powered, then the data in memory can be trusted and you can make a backup before
sending the adapter to a Thales service centre for battery/HSM replacement.
Port Specifications
The USB-to-serial cable provides an RS232 port with pin outs as shown in
"Adapter serial connector" below
.
This port can be used for connecting a smart card reader or another serial device.
Figure 3: Adapter serial connector
Thales ProtectServer HSM 5.9.1 ProtectServer HSM and ProtectToolkit Installation and Configuration Guide