![TEXIO DCS-4605 Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/texio/dcs-4605/dcs-4605_instruction-manual_1097544071.webp)
59
4-3-2. Selecting the horizontal scale
Select horizontal
scale
To select the timebase (scale),
turn the TIME/DIV knob; left
(slow) or right (fast).
TIME/DIV
Range
1ns/div ~ 50s/div, 1-2.5-5-10
increment
The timebase indicator at the bottom of the display
updates the current horizontal scale.
4-3-3. Selecting the waveform update mode
Background
The display update mode is switched automatically
or manually according to the horizontal scale.
Main mode
Updates the whole displayed waveform at once.
The main mode is automatically selected when the
horizontal scale (timebase) is fast.
Horizontal scale
≤100ms/div
Trigger
All modes available
Roll mode
Updates and moves the waveform gradually from
the right side of the display to the left. The Roll
mode is automatically selected when the horizontal
scale (timebase) is 50ms or slower.
Main mode
Roll mode
Timebase
≥50ms/div (≤1.25MS/s)
Trigger
Auto mode only
Selecting the
Roll mode
manually
1. Press the Horizontal menu
key.
MENU