141
3-21-31. :SEARCH:TRIGger:BUS:B1:UART:TX:DATa:VALue
Set
Query
Description
Sets or queries the search triggering data value for the
UART bus when the bus is set to trigger on Tx Data.
Syntax
:SEARCH:TRIGger:BUS:B1:UART:TX:DATa:VALue
{string | ? }
Related commands :SEARCH:TRIGger:BUS:B1:UART:TX:DATa:SIZe
Parameter
<sting>
The number of characters in the string
depends on the data size setting. The
string must be enclosed in double quotes,
"string".
x = don’t care
1 = binary 1
0 = binary 0
Return Parameter
Returns the data value.
Example1
:SEARCH:TRIGger:BUS:B1:UART:CONDition TXDATA
:SEARCH:TRIGger:BUS:B1:UART:TX:DATa:SIZe 1
:SEARCH:TRIGger:BUS:B1:UART:TX:DATa:VALue
"1x1x0101"
Sets the value to 1x1x0101
Example 2
:SEARCH:TRIGger:BUS:B1:UART:TX:DATa:VALue?
1X1X0101
3-21-32. :SEARCH:TRIGger:BUS:B1:SPI:CONDition
Set
Query
Description
Sets or queries the SPI search triggering condition.
Syntax
:SEARCH:TRIGger:BUS:B1:SPI:CONDition {SS | MISO
| MOSI | MISOMOSI | ? }
Parameter
SS
Set to trigger on the Slave Selection
condition.
MISO
Set to trigger on the Master-In Slave-Out
condition.
MOSI
Set to trigger on the Master-Out Slave-In
condition.
MISOMOS
I
Set to trigger on the Master-In Slave-Out
and Master-Out Slave-In conditions.
Return Parameter
Returns the triggering condition.
Example
:SEARCH:TRIGger:BUS:B1:SPI:CONDition MISO
Sets the SPI bus to trigger on MISO.