29
Remove All
Items
Press
Remove All
to remove all the
measurement items.
2-2-4. Gated mode
Some automatic measurements can be limit
ed to a “gated” area
between cursors. Gating is useful for measuring a magnified
waveform or when using a fast time base. The Gated mode has
three possible configurations: Off (Full Record), Screen and
Between Cursors.
Set Gating Mode 1. Press the
Measure
key.
Measure
2. Press
Gating
from the bottom
menu.
3. Choose one of the gating modes
from the side menu:
Off (full
record)
,
Screen
,
Between Cursors.
Cursors On
Screen
If
Between Cursors
is selected, the
cursor positions can be edited by
using the cursor menu.
Page 34
2-2-5. Display All mode
Display All mode shows and updates all items from Voltage and
Time type measurements.
View
Measurement
Results
1. Press the
Measure
key.
Measure
2. Press
Display All
from the bottom
menu.
3. Press Source from the side menu
and choose a measurement
source.
Range
CH1~CH4, Math
4. The results of Voltage and Time type
measurements appear on the display.