Premier 48-W Quick Start Guide
INS531
7
Control Panel PCB Layout
1: AC Input
Connected to the 16.5V transformer.
DO NOT CONNECT THE MAINS SUPPLY TO THE AC INPUT
TERMINALS ON THE PCB.
2: Battery Connections
A 12V rechargeable battery must be connected to these terminals in
order to provide continuous system operation in the event of an AC
Mains failure. (protected by 1.6 Amp PTC Fuse)
3: Digicom Power & Inputs
These terminals provide un-fused power; remote reset and line fault
inputs and are normally used for connecting a stand-alone
communicator to the control panel.
4: Digicom Outputs
Outputs 1 to 8 are low current (100mA ‘-ve’ applied) and would
normally be used when connecting a stand-alone communicator to
the control panel. Each output is fully programmable.
5: Network Data Connections
Network 1 provides connection for the keypads and zone expanders.
The ‘+’ and ‘–’ terminals provide power whilst the ‘T’ transmits data
and ‘R’ receives data.
6: Network Data Indicators
The red LED indicates that data is flowing out of the control panel
and normally flashes very quickly. The green LED indicates that data
is flowing into the control panel and normally flashes slowly, the
green LED flashes faster as more devices are connected.
7: Auxiliary 12V Power
These terminals are for connecting devices that require 12V power
(protected by a 0.9A PTC fuse).
8: PTC Protection Fuses
The following fuses are provided:
•
PTC (0.9A) Auxiliary 12V Power fuse
•
PTC (0.9 A) Network 1 fuse
•
PTC (0.9 A) Bell/Strobe fuse
9: External Sounder Connections
These terminals are used for connecting to an external sounder unit.
10: Auxiliary Tamper Connections
These terminals can be used for monitoring the tamper loop of an
auxiliary device.
11: Loudspeaker Connections
These terminals can be used for connecting up to one 8
Ω
or two
16
Ω
loudspeakers.
12: Panel Outputs
Outputs 1 & 2 are 500mA ‘-ve’ applied, outputs 3 & 4 are 500mA
‘+ve’ applied and output 5 is a clean contact relay. These outputs
are all fully programmable.
13: Load Defaults Button
Press and hold this button whilst applying power to the control panel
to load the factory default settings. Press and hold this button for 7
seconds with power already on the panel to restore just the Engineer
code to the factory setting of
.
Loading the factory defaults can take up to 60 seconds to
complete.
Loading defaults will only be possible if the NVM has not been
locked.
For a complete list of factory defaults, see the
Premier Quick
Reference
supplied on the enclosed CD.
E ngineer R E M
OP T IO NS
Tamper
Dis able
1
2
3
4
5
7
9
10
11
12
20
16
19
6
13
14
18
17
15
21
22
23
24
25
26
27
28
30
31
32
10
0m
V
=
1
A
m
p
V
29
Содержание Premier Elite 48-W
Страница 1: ...INS531 Premier 48 W Quick Start Guide...
Страница 18: ...Premier 48 W Quick Start Guide 18 INS531 Notes...
Страница 19: ...Premier 48 W Quick Start Guide INS531 19 Notes...