Texecom Premier Elite 48-W Скачать руководство пользователя страница 10

Premier 48-W Quick Start Guide 

10 

 INS531 

5. Expander Engineer Keypad Functions 

The Engineers Keypad can be connected directly to the expander, 
and has the following features & functions. 

 

Learning & Deleting devices is not available from the 

engineer’s keypad. 

Change Device attributes 

Device attribute changes should be saved by either pressing the 

/

  key after each device change  or by pressing the 

/

 

key after scrolling through the devices and making multiple 
changes. 

Once changed device attributes will be updated on the next 
successful poll with the receiver, if however you wish to update the 
devices immediately please see Update Devices on page 11. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change 

Premier SmartKey™

 attributes 

Premier SmartKey™

  attribute changes should be saved by either 

pressing the 

  key after each 

Premier SmartKey™

  change  or by 

pressing the 

  key after scrolling through the devices and making 

multiple changes. 

 

Once changed 

Premier SmartKey™

  attributes will be updated the 

next time the 

Premier SmartKey™

 is powered on. 

/

 Key Functions 

When in Commission Mode (see page  14) pressing the 

/

 key 

will display further information about the device’s routing information 
and signal strength. 

No Hops 

In this example the device is “Home 
Running” 

  
  

 

1 Hop 

In this example the device is hopping 
through device 16 and the relevant 
signal strengths are shown 

  
 

 

2 Hops 

In this example the device is hopping 
through device 18 & 6 and the relevant 
signal strength is shown. 

    
 

 

 

 

     

  

      

 

Use 1 & 2 keys to change device attributes

1 = AUTO MODE (Default)

2  = ALWAYS AWAKE

      

 

     

    

     

  

/

/

/

/

/

 

 

   

  

      

    

Use 1 & 2 keys to change fob attributes

1 = LED On/Off (Default is On)

2 = Aux Off/On (Default is Off)

*SmartKey attributes will be updated the

 next time the fob is powered up.

      

    

/

/

/

/

Содержание Premier Elite 48-W

Страница 1: ...INS531 Premier 48 W Quick Start Guide...

Страница 2: ...nel 5 Control Panel Layout 6 Control Panel PCB Layout 7 4 Learning Devices 9 5 Expander Engineer Keypad Functions 10 Walktest Mode 12 6 Attributes Operation Modes 13 Polling 13 System Devices 13 Premi...

Страница 3: ...rect setup and operation of the Wireless Network it is important that the following procedures are used when learning and placing devices Learning Devices All devices should be learnt before they are...

Страница 4: ...that it powers If the total current exceeds the Rated Output for the grade you are installing to then an additional power supply is required Connecting AC Mains The AC Mains supply is connected to a...

Страница 5: ...black battery lead to the negative terminal The panel will only become live when the AC Mains is connected or the Battery Kick start button is pressed Connect the AC mains For a complete list of facto...

Страница 6: ...6 INS531 Control Panel Layout DANGE R HIGH VOLTAGE TF M 018 230V 0 0150A R E PLACE ME NT FUS E 0 125A 50 60Hz R ATE D VOLTAG E IS FAC TOR Y S E T AND C ANNOT B E ADJ US TE D Texecom Ltd CLAS S 2 Audi...

Страница 7: ...s are connected 7 Auxiliary 12V Power These terminals are for connecting devices that require 12V power protected by a 0 9A PTC fuse 8 PTC Protection Fuses The following fuses are provided PTC 0 9A Au...

Страница 8: ...ection Serial communications port for connecting to a PC via PC Com USB Com or Com IP for use with RICOCHET Monitor Software 24 Cover Tamper Disable Disables the lid tamper 25 Cover Tamper Provides ta...

Страница 9: ...panel keypad shows the average of the hopped signal strengths Follow the instructions opposite to learn devices to the system once complete follow the instructions in the relevant control panel manua...

Страница 10: ...ved by either pressing the key after each Premier SmartKey change or by pressing the key after scrolling through the devices and making multiple changes Once changed Premier SmartKey attributes will b...

Страница 11: ...ry again If not in commission mode you should wait 15 minutes and try again Walktest Mode Used to initiate stop Walktest Mode If the Walktest broadcast message fails the following will be seen In this...

Страница 12: ...version of the Expander 3 Receiver is being Jammed 4 Commission Mode 5 the Wireless Network not the Premier Network 6 RICOCHET Panel Firmware 7 Not shown on Premier 48 W Device Status Indications On t...

Страница 13: ...r any of the inputs are triggered the zone which the device is mapped too will go active Switch 3 on the expander controls how MAG 2 COM reports to the control panel By default the switch is on and an...

Страница 14: ...he receiver Closing the tamper circuit will activate the LED for a short period of time whilst communication with the receiver is established The LED will flash indicating the device is trying to comm...

Страница 15: ...ed zones on expanders are used correctly and any wireless devices or keypad zones are NOT using the zone numbers associated with the expander address The table below details which zones are fixed for...

Страница 16: ...attery Capacity 1 2Ah to 7Ah Remote Keypads Up to four Expanders 3 8XP Output Modules 2 Zones 0 expandable to 48 Panel Outputs 8 PGM X 2 100mA switched to 0V 500mA switched to 0V Speaker Output Minimu...

Страница 17: ...ucts are designed for reliable trouble free operation Quality is carefully monitored by extensive computerised testing As a result the Premier 48 W is covered by a two year warranty against defects in...

Страница 18: ...Premier 48 W Quick Start Guide 18 INS531 Notes...

Страница 19: ...Premier 48 W Quick Start Guide INS531 19 Notes...

Страница 20: ...Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at local rate from a BT landline Calls from other networks may vary International Customers Tel 44 1278 68619...