Hardware Initialization States
3-22
Table 3–2. State of the Status Register (17 bit) after RESET Low-to-High
(Bits 5 through 16 are left uninitialized)
Bit
Bit Name
Initialized Value
Description
0
XM
0
Extended sign mode disabled
1
UM
0
Unsigned multiplier mode disabled (allows signed multiplier mode)
2
OM
0
Overflow mode disabled (allows ALU normal mode)
3
FM
0
Shift mode for fractional multiplication disabled (allows unsigned
fractional/integer arithmetic)
4
IM
0
Global interrupt enable bit
5
(reserved)
Reserved for future use
6
XZF
Transfer equal-to-zero status bit
7
XSF
Transfer sign status bit
8
RCF
Auxiliary register carry-out status bit
9
RZF
Auxiliary register equal-to-zero status bit
10
OF
Same state as
Accumulator overflow status bit
11
SF
before RESET
Accumulator sign status bit (extended 17th bit)
12
ZF
Accumulator equal-to-zero status bit (16 bits)
13
CF
Accumulator carry-out status bit (16th ALU bit)
14
TF1
Test flag 1
15
TF2
Test flag 2
16
TAG
Memory tag