Memory Organization: RAM and ROM
2-20
Note:
Instructions with References
Care must be taken when employing instructions that have either long string
constant references or look-up table references. These instructions will
execute properly only if the address of the instruction and the address of the
data reference are within the same block.
The protection modes are implemented on the C6xx as follows. Within the
ROM is a dedicated storage for the block protection word (address 0x7FFE).
The block protection word is divided into two 6-bit fields and two single-bit
fields. The remainder of the 17-bit word is broken into three single-bit fields
which are reserved for future use.
Block Protection Word
address 0x7FFE
(17-bit wide location)
WRITE only
16
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
R
R
TM
TM
TM TM TM TM
GP BP
R
FM FM FM FM FM FM
05
04
03
02
01
00
05
04
03
02
01
00
TM : True Protection Marker (N
TM
)
GP : Global Protection (0 value protects)
FM : False Protection Marker (N
FM
)
BP : Block Protection (0 value protects)
R : Reserved for future use (must be 1)
1 : Default value of cells on erasure
The two 6-bit fields are designated as the true protection marker, (TM5 through
TM0) and the false protection marker, (FM5 through FM0). When setting up
a partition for partial ROM protection, the address of the partition must be spe-
cified as:
Содержание MSP50C6xx
Страница 1: ...MSP50C6xx Mixed Signal Processor User s Guide Mixed Signal Products SPSU014A Printed on Recycled Paper...
Страница 6: ...vi...
Страница 14: ...xiv...
Страница 24: ...1 10...
Страница 296: ...Instruction Set Summay 4 210 Assembly Language Instructions...
Страница 332: ...Implementation Details 5 36 R7 Return Addr Return Addr Param 2 Param 2 Param 1 Param 1 R5 Stack data Function call...
Страница 366: ...6 12...