![Texas Instruments CC2533 Скачать руководство пользователя страница 216](http://html.mh-extra.com/html/texas-instruments/cc2533/cc2533_user-manual_1094592216.webp)
Timer 2 Registers
T2CTRL (0x94)
–
Timer 2 Control Register
Bit
Name
Reset
R/W
Function
No.
7:4
–
0
R0
Reserved. Read as 0
3
LATCH_MODE
0
R/W
0:
Reading T2M0 with
T2MSEL.T2MSEL
= 000 latches the high byte of the timer,
making it ready to be read from T2M1. Reading T2MOVF0 with
T2MSEL.T2MOVFSEL
= 000 latches the two most-significant bytes of the overflow counter, making it
possible to read these from T2MOVF1 and T2MOVF2.
1:
Reading T2M0 with
T2MSEL.T2MSEL
= 000 latches the high byte of the timer and
the entire overflow counter at once, making it possible to read the values from
T2M1
,
T2MOVF0
,
T2MOVF1
, and
T2MOVF2
.
2
STATE
0
R
State of Timer 2
0:
Timer idle
1:
Timer running
1
SYNC
1
R/W
0:
Starting and stopping of timer is immediate, i.e., synchronous with clk_rf_32m.
1:
Starting and stopping of timer happens at the first positive edge of the 32-kHz clock.
Read
for more details regarding timer start and stop.
0
RUN
0
R/W
Write 1 to start timer, write 0 to stop timer. When read, it returns the last written
value.
T2EVTCFG (0x9C)
–
Timer 2 Event Configuration (CC253x/CC2540)
Bit
Name
Reset
R/W
Function
No.
7
–
0
R0
Reserved. Read as 0
6:4
TIMER2_EVENT2_CFG
0
R/W
Selects the event that triggers a T2_EVENT2 pulse
000: t2_per_event
001: t2_cmp1_event
010: t2_cmp2_event
011: t2ovf_per_event
100: t2ovf_cmp1_event
101: t2ovf_cmp2_event
110: Reserved
111: No event
3
–
0
R0
Reserved. Read as 0
2:0
TIMER2_EVENT1_CFG
0
R/W
Selects the event that triggers a T2_EVENT1 pulse
000: t2_per_event
001: t2_cmp1_event
010: t2_cmp2_event
011: t2ovf_per_event
100: t2ovf_cmp1_event
101: t2ovf_cmp2_event
110: Reserved
111: No event
216