![Texas Instruments CC2533 Скачать руководство пользователя страница 112](http://html.mh-extra.com/html/texas-instruments/cc2533/cc2533_user-manual_1094592112.webp)
FFFFh
T1CC0
T1CC0
T1CC0
T1CCn
T1CCn
T1CCn
0000h
0 - Set Output on Compare
1 - Clear Output on Compare
4 - Clear Output on Compare-Up,
Set on 0
5 - Clear When T1CC0, Set When T1CCn
6 - Set When T1CC0, Clear When T1CCn
2 - Toggle Output on Compare
3 - Set Output on Compare-Up,
Clear on 0
T0311-01
Output Compare Mode
Figure 9-4. Output Compare Modes, Timer Free-Running Mode
112
Timer 1 (16-Bit Timer)
SWRU191C
–
April 2009
–
Revised January 2012
Copyright
©
2009
–
2012, Texas Instruments Incorporated