Battery Monitor Registers
BATTMON (0x6264)
–
Battery Monitor
Bit
Name
Reset
R/W
Description
7
–
0
R0
Reserved. Always read 0
6
BATTMON_OUT
0
R
Result from the battery monitor.
1: Voltage is above value set in
BATTMON_VOLTAGE.
0: Voltage is below the value set in
BATTMON_VOLTAGE.
Note that the value of
BATTMON_OUT
is undefined except when
BATTMON_PD
is 0 and has
been 0 for 2 us.
5:1
BATTMON_VOLTAGE
11100
R/W
Controls the trigger point for the battery monitor. The step size is 24 mV for the first 23 settings,
and then 169 mV (unless temperature-sense mode is enabled; see
for details).
Range to be used: 3
–
31
3: 1.93 V
4: 1.93 V + (4
–
3)
×
0.024 V = 1.954 V
5: 1.93 V + (5
–
3)
×
0.024 V = 1.978 V
6: 1.93 V + (6
–
3)
×
0.024 V = 2.002 V
7: 1.93 V + (7
–
3)
×
0.024 V = 2.026 V
8: 1.93 V + (8
–
3)
×
0.024 V = 2.050 V
9: 1.93 V + (9
–
3)
×
0.024 V = 2.074 V
10: 1.93 V + (10
–
3)
×
0.024 V = 2.098 V
11: 1.93 V + (11
–
3)
×
0.024 V = 2.122 V
12: 1.93 V + (12
–
3)
×
0.024 V = 2.146 V
13: 1.93 V + (13
–
3)
×
0.024 V = 2.170 V
14: 1.93 V + (14
–
3)
×
0.024 V = 2.194 V
15: 1.93 V + (15
–
3)
×
0.024 V = 2.218 V
16: 1.93 V + (16
–
3)
×
0.024 V = 2.242 V
17: 1.93 V + (17
–
3)
×
0.024 V = 2.266 V
18: 1.93 V + (18
–
3)
×
0.024 V = 2.290 V
19: 1.93 V + (19
–
3)
×
0.024 V = 2.314 V
20: 1.93 V + (20
–
3)
×
0.024 V = 2.338 V
21: 1.93 V + (21
–
3)
×
0.024 V = 2.362 V
22: 1.93 V + (22
–
3)
×
0.024 V = 2.386 V
23: 1.93 V + (23
–
3)
×
0.024 V = 2.410 V
24: 1.93 V + (24
–
3)
×
0.024 V = 2.434 V
25: 1.93 V + (25
–
3)
×
0.024 V = 2.458 V
26: 1.93 V + (26
–
3)
×
0.024 V = 2.482 V
27: 2.482 V + (27
–
26)
×
0.169 V = 2.651 V
28: 2.482 V + (28
–
26)
×
0.169 V = 2.820 V
29: 2.482 V + (29
–
26)
×
0.169 V = 2.989 V
30: 2.482 V + (30
–
26)
×
0.169 V = 3.158 V
31 : 2.48 2V + (31
–
26)
×
0.169 V = 3.327 V
0
BATTMON_PD
1
R/W
Turns on the battery monitor. Wait at least 2
µ
s before reading
BATTMON_OUT
.
0: Enable the battery monitor.
1: Disable the battery monitor.
One should turn the battery monitor off (
BATTMON_PD = 1
) after reading out the measurement
BATTMON_OUT
in order to save power, as the battery monitor consumes power when enabled
(
BATTMON_PD = 0
).
MONMUX (0x61A6)
–
Monitor MUX
Bit
Name
Reset
R/W
Description
7:1
–
-
-
Reserved
0
BATTMON_INPUT
0
R/W
Determines the input to the battery moitor:
0: Supply voltage (
AVDD5
)
1: Voltage from the temperature sensor, which needs to be enabled using the
ATEST.ATESTCTRL
register; described in
148
Battery Monitor